MaintainX Asset Hub logo
EnterprisePricing
Advantage

Advantage Temperature Control Unit SK-645

Need answers fast?
Explore the manual using AI.

Advantage Temperature Control Unit SK-645
Advantage Temperature Control Unit SK-645

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Advantage Temperature Control Unit SK-645

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Advantage Temperature Control Unit SK-645

Advantage Temperature Control Unit SK-645

Create an account to install this asset package.

Maintenance Plans for Advantage Temperature Control Unit Model SK-645

Integrate maintenance plans directly into your work orders in MaintainX.

Heating Cylinder Replacement

Check mark

Preparation

Check mark

Disengage operations and ensure all system pressure is relieved

Check mark

Verify the unit's pressure gauges read '0'

Check mark

Disengage main power supply

Check mark

Verify the Power light on the display is 'off'

Check mark

Access and Drainage

Check mark

Remove the lift-off access panel and set aside

Check mark

Drain machine by removing the pump casing drain plug

Check mark

Heater Disconnection

Run this procedureArrow right

Sensor Probe Maintenance

Check mark

Reconnection Procedure

Check mark

Unplug the sensor probe connection

Check mark

Shake out water from the service connection

Check mark

Replug the sensor probe connection

Check mark

Did the error display change to Solid Red?

Check mark

Press the Start push button to clear the error display

Check mark

Replacement Procedure

Check mark

Stop process operations as described in section 3.4 of the manual

Check mark

Ensure all process pressure is relieved and pressure gauges read '0' pressure

Run this procedureArrow right

Cooling Valve Maintenance

Check mark

Initial Safety and Preparation

Check mark

Disengage process operations and verify all system pressure is relieved and the unit's pressure gauges read '0'.

Check mark

Disengage main power supply and verify the Power light on the display is 'off'.

Check mark

Access and Disconnect

Check mark

Remove the lift-off access panel and set aside.

Check mark

Disconnect the valve wiring harness.

Check mark

Remove the AVT valve's drip cover.

Check mark

Motor/Gearbox Service

Check mark

Remove the 2 mounting screws securing the motor/gearbox assembly to the valve bracket.

Run this procedureArrow right

Flow Meter Maintenance

Check mark

Preparation

Check mark

Reduce process water temperature to below 85°F.

Check mark

Disengage process operations.

Check mark

Verify all system pressure is relieved and the pressure gauges read "0".

Check mark

Power Disengagement

Check mark

Disengage main power supply.

Check mark

Verify the Power light on the display is "off".

Check mark

Access Cooling Cylinder

Check mark

Remove the lift-off access panel to access the cooling cylinder.

Run this procedureArrow right

Pressure Switch Maintenance

Check mark

Preparation and Safety

Check mark

Shut down unit operations according to section 3.4 in the manual

Check mark

Ensure proper lock-out procedures are followed

Check mark

Confirm system pressure is eliminated and pressure gauges read '0'

Check mark

Pressure Switch Removal

Check mark

Drain unit by removing the pump casing drain plug

Check mark

Remove the capillary connection from the cooling cylinder to the pressure switch

Check mark

Remove the brass elbow mounted on the pressure switch

Check mark

Disconnect the electrical connections to the pressure switch

Run this procedureArrow right

Parts for Advantage Temperature Control Unit SK-645

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Motor/Pump Assembly AS5 1HP AS5 2/4/3/60

6207010

Impeller B2-5264 4.75" AS5

4310603

Motor AE5/AS5/A5W 1HP #S-2773R

4757863

Adapter - iron C2-4551 AS5

414

Pump case - iron D2-1839 AS5

771599

Motor/Pump Assembly AS5 1HP AS5 2/4/3/60

6207010

Impeller B2-5264 4.75" AS5

4310603

Motor AE5/AS5/A5W 1HP #S-2773R

4757863

Adapter - iron C2-4551 AS5

414

Pump case - iron D2-1839 AS5

771599

Motor/Pump Assembly AS5 1HP AS5 2/4/3/60

6207010

Impeller B2-5264 4.75" AS5

4310603

Motor AE5/AS5/A5W 1HP #S-2773R

4757863

Adapter - iron C2-4551 AS5

414

Pump case - iron D2-1839 AS5

771599

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Advantage

Explore Other Assets