MaintainX Asset Hub logo
EnterprisePricing
Advantage

Advantage Temperature Control Unit SK-635

Need answers fast?
Explore the manual using AI.

Advantage Temperature Control Unit SK-635
Advantage Temperature Control Unit SK-635

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Advantage Temperature Control Unit SK-635

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Advantage Temperature Control Unit SK-635

Advantage Temperature Control Unit SK-635

Create an account to install this asset package.

Maintenance Plans for Advantage Temperature Control Unit Model SK-635

Integrate maintenance plans directly into your work orders in MaintainX.

Instrument Controller Maintenance

Check mark

Preparation

Check mark

Disengage process operations according to the procedure outlined in section 3.4

Check mark

Ensure all system pressure is relieved and the unit's pressure gauges read '0'

Check mark

Disengage main power supply

Check mark

Verify the Power light on the display is 'off'

Check mark

Panel and Instrument Removal

Check mark

Remove the thermoformed front panel and set aside

Check mark

Open the hinged electrical cabinet panel cover

Check mark

Remove electrical connections

Run this procedureArrow right

Pressure Switch Maintenance

Check mark

Pre-maintenance Preparation

Check mark

Become familiar with the manual and operating characteristics of the equipment.

Check mark

Ensure proper operator training, installation, operation, and maintenance of the water temperature controller.

Check mark

Safety Considerations

Check mark

Follow proper lock-out procedures.

Check mark

Is the system pressure eliminated and the unit's pressure gauges reading '0' pressure?

Check mark

Pressure Switch Replacement

Check mark

Shut down unit operations according to section 3.4 in the manual.

Check mark

Drain unit by removing the pump casing drain plug.

Run this procedureArrow right

1 Yearly Probe Calibration

Check mark

Preparation

Check mark

Disengage process operations and verify all system pressure is relieved and the unit's pressure gauges read '0'.

Check mark

Disengage main power supply and verify the Power light on the display is 'off'.

Check mark

Probe Removal and Replacement

Check mark

Remove the 'To Process' temperature probe and insert a 1/2" plug in its place.

Check mark

Ice Water Bath Preparation

Check mark

Prepare an ice water bath.

Check mark

Record the temperature of the ice water bath using an accurate digital thermometer.

Check mark

Calibration Procedure

Run this procedureArrow right

Pump Seal Replacement

Check mark

Preparation

Check mark

Disengage process operations and relieve all system pressure.

Check mark

Disengage main power supply.

Check mark

Verify the Power light on the display is 'off'.

Check mark

Access Panel Removal

Check mark

Remove the lift-off access panel and set aside.

Check mark

Remove the thermoformed panel attached by 4 small screws.

Check mark

Drain and Disconnect

Check mark

Drain machine by removing the pump casing drain plug.

Run this procedureArrow right

Sensor Probe Maintenance

Check mark

Reconnection Procedure

Check mark

Unplug the sensor probe connection

Check mark

Shake out water from the service connection

Check mark

Replug the sensor probe connection

Check mark

Did the error display change to Solid Red?

Check mark

Replacement Procedure

Check mark

Stop process operations as described in section 3.4 of the manual

Check mark

Ensure all process pressure is relieved and pressure gauges read '0' pressure

Check mark

Drain the unit by removing the pump casing drain plug

Run this procedureArrow right

Parts for Advantage Temperature Control Unit SK-635

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Motor/Pump Assembly AS5 3/4HP ODP 230/460

6207000

Impeller B2-5264 4.5" AS5

4310602

Impeller AS5 #100345 4.5" MFG after 2-97

4310611

Motor AE5/AS5/A5W 3/4HP #S-2772R

4757862

Motor 3/4HP 113-000-354T 2/4/3/60

4714466

Motor/Pump Assembly AS5 3/4HP ODP 230/460

6207000

Impeller B2-5264 4.5" AS5

4310602

Impeller AS5 #100345 4.5" MFG after 2-97

4310611

Motor AE5/AS5/A5W 3/4HP #S-2772R

4757862

Motor 3/4HP 113-000-354T 2/4/3/60

4714466

Motor/Pump Assembly AS5 3/4HP ODP 230/460

6207000

Impeller B2-5264 4.5" AS5

4310602

Impeller AS5 #100345 4.5" MFG after 2-97

4310611

Motor AE5/AS5/A5W 3/4HP #S-2772R

4757862

Motor 3/4HP 113-000-354T 2/4/3/60

4714466

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Advantage

Explore Other Assets