MaintainX Asset Hub logo
EnterprisePricing
Advantage

Advantage Temperature Control Unit SK-1045-LEP

Need answers fast?
Explore the manual using AI.

Advantage Temperature Control Unit SK-1045-LEP
Advantage Temperature Control Unit SK-1045-LEP

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Advantage Temperature Control Unit SK-1045-LEP

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Advantage Temperature Control Unit SK-1045-LEP

Advantage Temperature Control Unit SK-1045-LEP

Create an account to install this asset package.

Maintenance Plans for Advantage Temperature Control Unit Model SK-1045-LEP

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Probe Calibration

Check mark

Preparation

Check mark

Disengage process operations and verify all system pressure is relieved and the unit's pressure gauges read '0'.

Check mark

Disengage main power supply and verify the Power light on the display is 'off'.

Check mark

Probe Removal and Replacement

Check mark

Remove the 'To Process' temperature probe and insert a 1/2" plug in its place.

Check mark

Calibration Setup

Check mark

Prepare an ice water bath and place an accurate digital thermometer in it.

Check mark

Place the probe in the ice water bath.

Check mark

Calibration Process

Run this procedureArrow right

Electronic Instrument Maintenance

Check mark

In Warranty Service Incident

Check mark

Call the factory for diagnostic assistance

Check mark

Is the control instrument determined to be at fault?

Check mark

Send a new or reconditioned instrument as a replacement if the instrument is at fault

Check mark

Return the defective instrument freight pre-paid for full credit

Check mark

Was the defective instrument returned?

Check mark

Pay for the instrument if it was not returned

Check mark

Out of Warranty Service Incident

Check mark

Call the factory for diagnostic assistance

Run this procedureArrow right

Flow Meter Maintenance

Check mark

Preparation

Check mark

Reduce process water temperature to below 85 degrees F.

Check mark

Disengage process operations and verify all system pressure is relieved and the pressure gauges read "0".

Check mark

Disengage main power supply and verify the Power light on the display is "off".

Check mark

Access Cooling Cylinder

Check mark

Remove the lift-off access panel to access the cooling cylinder.

Check mark

Disconnect the AVT valve cable, the hall effect sensor cable, the pressure gauge and pressure switch lines.

Check mark

Remove Cooling Cylinder

Check mark

Remove the 4 mounting bolts that hold the cooling cylinder to the pump volute.

Run this procedureArrow right

Instrument Controller Maintenance

Check mark

Preparation

Check mark

Disengage process operations according to the procedure outlined in section 3.4.

Check mark

Ensure all system pressure is relieved and the unit's pressure gauges read '0'.

Check mark

Disengage main power supply.

Check mark

Verify the Power light on the display is 'off'.

Check mark

Panel and Instrument Removal

Check mark

Remove the thermoformed front panel and set aside.

Check mark

Open the hinged electrical cabinet panel cover.

Check mark

Remove the large molex connector.

Run this procedureArrow right

Pressure Switch Maintenance

Check mark

Preparation

Check mark

Shut down unit operations according to section 3.4 in this manual.

Check mark

Ensure proper lock-out procedures are followed.

Check mark

Ensure system pressure is eliminated and the unit's pressure gauges read '0' pressure.

Check mark

Pressure Switch Removal

Check mark

Drain unit by removing the pump casing drain plug.

Check mark

Remove the capillary connection from the cooling cylinder to the pressure switch.

Check mark

Remove the brass elbow mounted on the pressure switch.

Check mark

Remove the electrical connections to the pressure switch.

Run this procedureArrow right

Parts for Advantage Temperature Control Unit SK-1045-LEP

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Motor/Pump Assembly AS5 1HP AS5 2/4/3/60

6207010

Adapter - Iron C2-4551 AS5

414

Pump Case - Iron D2-1839 AS5

771599

Tank Gasket 2-3/8" A-9159 AS5

3444400

Tank Gasket 4-1/2" A2-8748 AS5

3444401

Motor/Pump Assembly AS5 1HP AS5 2/4/3/60

6207010

Adapter - Iron C2-4551 AS5

414

Pump Case - Iron D2-1839 AS5

771599

Tank Gasket 2-3/8" A-9159 AS5

3444400

Tank Gasket 4-1/2" A2-8748 AS5

3444401

Motor/Pump Assembly AS5 1HP AS5 2/4/3/60

6207010

Adapter - Iron C2-4551 AS5

414

Pump Case - Iron D2-1839 AS5

771599

Tank Gasket 2-3/8" A-9159 AS5

3444400

Tank Gasket 4-1/2" A2-8748 AS5

3444401

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Advantage

Explore Other Assets