MaintainX, an Autodesk company
EnterprisePricing
York

York Rooftop Unit Y13BC04C1LABAB

Need answers fast?
Explore the manual using AI.

York Rooftop Unit Y13BC04C1LABAB
York Rooftop Unit Y13BC04C1LABAB

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for York Rooftop Unit Y13BC04C1LABAB

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

York Rooftop Unit Y13BC04C1LABAB

York Rooftop Unit Y13BC04C1LABAB

Create an account to install this asset package.

Maintenance Plans for York Rooftop Unit Model Y13BC04C1LABAB

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Indoor Blower Motor Check

Check mark

Safety Precautions

Check mark

Ensure power is disconnected from the unit

Check mark

Do not lubricate bearings with the unit in operation

Check mark

Motor Inspection

Check mark

Check motor for accumulations of dust blocking cooling slots

Check mark

Check drive components for issues

Check mark

Check that all mounting bolts are tight

Check mark

Replacement and Repair

Check mark

Replace defective parts as required

Run this procedureArrow right

2 Monthly Indoor Blower Bearing Lubrication

Check mark

Safety Precautions

Check mark

Ensure power is disconnected from the unit before maintenance

Check mark

Is the unit in operation?

Check mark

Confirm that the unit is not in operation before proceeding

Check mark

Bypass Mode Configuration

Check mark

Set the switches on the front of the bypass box

Check mark

Is the drive in bypass mode if it has failed?

Check mark

Lubrication Process

Check mark

Select the operating speed (RPM)

Run this procedureArrow right

10 Yearly Outdoor Fan, Vendor Motors Maintenance

Check mark

Safety Precautions

Check mark

Shut off all power to the unit

Check mark

Label all wires prior to disconnection

Check mark

Motor Maintenance

Check mark

Verify that outdoor fan motors are permanently lubricated

Check mark

Is lubrication desired for outdoor fan motors?

Check mark

Verify that vendor motors are factory lubricated for an estimated 10-year life

Check mark

Post-Maintenance Verification

Check mark

Verify proper operation after servicing

Run this procedureArrow right

3 Yearly Indoor Blower Motor Pipe Plugs Change

Check mark

Safety Precautions

Check mark

Disconnect power from the blower motor unit

Check mark

Ensure the unit is not in operation before lubricating bearings

Check mark

Pipe Plugs Removal and Cleaning

Check mark

Remove both pipe plugs at each end shell

Check mark

Clean out any hardened grease or foreign matter

Check mark

Grease Fitting Installation and Lubrication

Check mark

Replace one plug on each end with a clean grease fitting

Check mark

Pump grease (Chevron SRI-2 or equivalent) into the bearing cavity using a low pressure grease gun until new grease shows at the open port

Run this procedureArrow right

Belt Tension Adjustment

Check mark

Pre-Adjustment Check

Check mark

Is the unit equipped with power exhaust fans or a return air fan?

Check mark

Belt Tension Adjustment Procedure

Check mark

Loosen the four bolts holding the motor base to the channels

Check mark

Adjust the belt by turning nuts 'A' (see detail 'B')

Check mark

Apply a perpendicular force to one belt at the midpoint of the span using a belt tension checker

Check mark

Enter the deflection distance obtained (in inches)

Check mark

Select the fan type and motor horsepower

Check mark

Select belt type

Run this procedureArrow right

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from York

Explore Other Assets