

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

York Rooftop Unit Y13AC04C1LABAB
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Refriegeration System Check
Refrigeration System Charge
Verify the system charge
Thermal Expansion Valves (TXVs)
Enter the number of independent refrigeration systems
Measure the superheat leaving the evaporator coil
Is adjustment of the superheat necessary?
Moisture/Liquid Sight Glass
Is the flow of liquid clear?
Are there any bubbles in the sight glass?
3 Yearly Indoor Blower Motor Pipe Plugs Change
Safety Precautions
Disconnect power from the blower motor unit
Ensure the unit is not in operation before lubricating bearings
Pipe Plugs Removal and Cleaning
Remove both pipe plugs at each end shell
Clean out any hardened grease or foreign matter
Grease Fitting Installation and Lubrication
Replace one plug on each end with a clean grease fitting
Using a low pressure grease gun, pump grease into the bearing cavity until new grease shows at the open port
1 Monthly Filters Maintenance
Safety Precautions
Shut off all power to the unit
Label all wires prior to disconnection
Filter Inspection and Replacement
Inspect filters
Filter type
Is replacement or cleaning necessary?
Replace or clean filter as necessary
Verify dimensional size of replacement filter
2 Monthly Indoor Blower Bearing Lubrication
Safety Precautions
Ensure power is disconnected from the unit before maintenance
Is the unit in operation?
Bypass Mode Configuration
Is the bypass VFD switched by hand on the front of the bypass enclosure?
Set the switches on the front of the bypass box
Lubrication Process
Select the operating speed (RPM) and shaft size (Inches)
Use premium quality NLGI 2 grade multi-purpose roller bearing grease
Supply Air Drive Adjustment
Pre-Adjustment Checks
Review installation for errors, leaks, or undesirable system effects
Ensure blower speed changes are necessary and safe
Blower Speed Adjustment
Enter the specified CFM
Enter the measured CFM
Enter the PD of the standard sheave
Calculate the PD of the new sheave using the formula: (Specified CFM/Measured CFM) X PD of standard sheave
Select the new motor sheave based on the calculated PD and reference tables
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













