Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

York Rooftop Unit Y13FC04C1LABAB
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
10 Yearly Outdoor Fan, Vendor Motors Maintenance
CAUTION: Prior to any of the following maintenance procedures, shut off all power to the unit. Failure to do so could cause personal injury. Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
MOTORS: Outdoor fan motors are permanently lubricated and require no maintenance. Lubrication, if desired, is to be performed by a qualified service agency. Ventor motors are factory lubricated for an estimated 10-year life.
Power to the unit shut off?
All wires labeled prior to disconnection?
Proper operation verified after servicing?
Sign off on the maintenance procedure
Belt Tension Adjustment
CAUTION: This procedure requires trained personnel with PPE!
Is the unit equipped with power exhaust fans or a return air fan?
If yes, check belt tension and adjust as necessary
Loosen the four bolts holding the motor base to the channels
Adjust the belt by turning nuts 'A'
Enter the deflection distance from the normal position
Use the recommended deflection force per the Belt Adjustment Table
Tension new belts at the maximum deflection force recommended
Check the belt tension at least two times during the first 24 hours of operation
3 Yearly Indoor Blower Motor Pipe Plugs Change
WARNING: Perform all maintenance operations on the blower motor with power disconnected from the unit. Do not attempt to lubricate bearings with the unit in operation.
Power disconnected from the unit?
Unit not in operation?
If desired, every three years remove both pipe plugs at each end shell and clean out any hardened grease or foreign matter.
Both pipe plugs removed and cleaned?
Replace one plug on each end with a clean grease fitting.
One plug on each end replaced with a clean grease fitting?
Using a low pressure grease gun, pump grease (Chevron SRI-2 or equivalent) into the bearing cavity until new grease shows at the open port. Do not over-lubricate.
Grease pumped into the bearing cavity until new grease shows at the open port?
Supply Air Drive Adjustment
CAUTION: Before making any blower speed changes review the installation for any installation errors, leaks or undesirable systems effects that can result in loss of air flow. Even small changes in blower speed can result in substantial changes in static pressure and BHP.
BHP or AMP draw of the blower motor will increase by the cube ratio of the blower speed. Static pressure will increase by the square ratio of the blower speed.
Tables 24 and 25 are for reference only. All blower speed changes must be made by qualified personnel with strict adherence to the fan laws.
Measured CFM based on Figures 58 and 59
Specified CFM
PD of standard sheave
PD of new sheave
New drive speed
New supply air
1 Monthly Filters Maintenance
CAUTION: Prior to any of the following maintenance procedures, shut off all power to the unit. Failure to do so could cause personal injury. Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
FILTERS: Inspect once a month. Replace disposable or clean permanent type as necessary. The dimensional size of the replacement filter must be the same as the replaced filter. Refer to Table 9;
Power to the unit shut off?
All wires labeled prior to disconnection?
Filters inspected?
Type of filter maintenance performed
Replacement filter of the same dimensional size?
Proper operation verified after servicing?
Sign off on the monthly filters maintenance
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX