Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

York Rooftop Unit Y12EC04C1LABAB
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Monthly Filters Maintenance
CAUTION: Prior to any of the following maintenance procedures, shut off all power to the unit. Failure to do so could cause personal injury. Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
FILTERS: Inspect once a month. Replace disposable or clean permanent type as necessary. The dimensional size of the replacement filter must be the same as the replaced filter. Refer to Table 9;
Power to the unit shut off?
All wires labeled prior to disconnection?
Filters inspected?
Type of filter maintenance performed
Replacement filter of the same dimensional size?
Sign off on the monthly filters maintenance
10 Yearly Outdoor Fan, Vendor Motors Maintenance
CAUTION: Prior to any of the following maintenance procedures, shut off all power to the unit. Failure to do so could cause personal injury. Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper operation after servicing.
MOTORS: Outdoor fan motors are permanently lubricated and require no maintenance. Lubrication, if desired, is to be performed by a qualified service agency. Ventor motors are factory lubricated for an estimated 10-year life.
Power to the unit shut off?
All wires labeled prior to disconnection?
Verified proper operation after servicing?
Sign off on the maintenance
Refriegeration System Check
Check if the system is fully factory charged with R-22
Verify the correct charge appears on the unit nameplate
Check the Thermal Expansion Valves
Check if the superheat on each valve is adjustable
Check the moisture/liquid sight glass
Check if a clear flow of liquid indicates the unit is properly charged
Check if any bubbles indicate the system is undercharged or noncondensables may exist
Check the color of the moisture indicator
Check the filter drier
Supply Air Drive Adjustment
CAUTION: Before making any blower speed changes review the installation for any installation errors, leaks or undesirable systems effects that can result in loss of air flow. Even small changes in blower speed can result in substantial changes in static pressure and BHP. BHP or AMP draw of the blower motor will increase by the cube ratio of the blower speed. Static pressure will increase by the square ratio of the blower speed.
Tables 24 and 25 are for reference only. All blower speed changes must be made by qualified personnel with strict adherence to the fan laws.
Enter the measured CFM based on Figures 58 and 59
Enter the specified CFM
Enter the PD of standard sheave
Use the equation (Specified CFM/Measured CFM) X PD of standard sheave = PD of new sheave to calculate the PD of new sheave.
Enter the PD of new sheave calculated from the equation
Use the 30 ton Table 35 to select a Browning 2B5V74 which will increase the speed of the unit's drive and its supply air CFM 108.7%.
Enter the new drive speed
2 Monthly Indoor Blower Bearing Lubrication
CAUTION: Damage can occur if the bearings are over lubricated. Use grease sparingly.
To go to bypass mode, the bypass VFD installed in this unit must be switched by hand on the front of the bypass enclosure in the fan cabinet of the rooftop unit. It does not automatically go to bypass mode if the drive fails.
The switches on the front of the bypass box control its run mode. For normal running:
If the drive fails, switch the BYPASS/OFF/DRIVE switch to BYPASS. If there is a call for the fan, it will go to full speed. If there are VAV boxes, connect them to the circuit at TB1/6 and they will be driven open in bypass mode.
WARNING: Perform all maintenance operations on the blower motor with power disconnected from the unit. Do not attempt to lubricate bearings with the unit in operation.
Indoor Blower Bearing Lubrication Schedule
Fan Drives
Sign off on the blower bearing lubrication
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX