Weil-McLain Water & Steam Boilers 1180
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Boiler Inspection
Safety Precautions
Check for propane gas odor near the floor
Is there any unusual odor detected?
Verify the odorant level of the propane gas
Boiler and System Inspection
Inspect boiler and system for gas leaks
Consulted propane supplier about gas leak detector installation
Lighting the Burner
Was the burner lit by a qualified service technician?
Boiler Check
Safety Precautions
Ensure boiler is sealed gas-tight to prevent flue gas leakage.
Handle ceramic fiber and fiberglass materials with care.
Boiler Inspection
Remove boiler jacket side and top panels.
Start burner and observe all sealing points.
Chalk mark any areas not gas-tight
Sealing Procedure
Use silicone sealant on section flueways.
Burner And Damper Adjustment
Initial Setup
Lock open flue transition damper
Ensure boiler is filled with water before firing
Burner Adjustment
Refer to burner manual for start-up and service
Let burner advance to high fire and heat boiler to design conditions
Adjust burner using combustion test equipment for
Damper Adjustment
Adjust damper assembly to ensure 0.1" W.C. positive pressure at test opening
Skim Steam Boilers Adjustment
Pre-Skimming Preparation
Ensure all newly installed steam boilers are cleaned to remove oil.
Verify that no petroleum-based cleaning or sealing compounds are used in the boiler system.
Skimming Process
Remove 1½” plug from skim tapping tapping “A” and provide 1½” skim piping to floor drain.
Raise waterline to midpoint of skim piping.
Fire burner to maintain temperature below steaming rate during skimming process.
Feed in water to maintain water level and cycle burner to prevent rise in steam pressure.
Continue skimming until discharge is clear.
Access the parts list for your equipment in MaintainX.
Front Section
315-700-100
Intermediate Section, Regular
315-700-120
Intermediate Section With Special Side Tappings
315-700-130
Intermediate Section, Supply (Steam Boilers)
315-700-150
Intermediate Section, Tankless
315-700-140
Front Section
315-700-100
Intermediate Section, Regular
315-700-120
Intermediate Section With Special Side Tappings
315-700-130
Intermediate Section, Supply (Steam Boilers)
315-700-150
Intermediate Section, Tankless
315-700-140
Front Section
315-700-100
Intermediate Section, Regular
315-700-120
Intermediate Section With Special Side Tappings
315-700-130
Intermediate Section, Supply (Steam Boilers)
315-700-150
Intermediate Section, Tankless
315-700-140
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX