

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Weil-McLain Water & Steam Boilers 380
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Boiler Check
Safety Precautions
Ensure boiler is sealed gas-tight to prevent flue gas leakage.
Handle ceramic fiber and fiberglass materials with care.
Boiler Inspection
Remove boiler jacket side and top panels.
Start burner and observe all sealing points.
Chalk mark any areas not gas-tight
Sealing Procedure
Use silicone sealant on section flueways.
Skim Steam Boilers Adjustment
Pre-Adjustment Notice and Warning
NOTICE: Clean all newly installed steam boilers to remove oil.
WARNING: Do not use petroleum-based cleaning or sealing compounds in boiler system.
Skimming Preparation
Remove 1½” plug from skim tapping tapping “A” and provide 1½” skim piping to floor drain.
Raise waterline to midpoint of skim piping.
Skimming Process
Fire burner to maintain temperature below steaming rate during skimming process.
Feed in water to maintain water level and cycle burner to prevent rise in steam pressure.
Burner And Damper Adjustment
Initial Setup
Lock open flue transition damper
Burner Adjustment
Refer to burner manual for start-up and service
Let burner advance to high fire and heat boiler to design conditions
Combustion Test Equipment Adjustment
Adjust burner for 12% (± ¼%) CO₂ for No. 2 fuel oil, 0 smoke
Adjust burner for 9 – 10% CO₂ natural gas; CO in flue gas not to exceed 50 ppm (0.01%)
Damper and Draft Control Adjustment
1 Yearly Boiler Inspection
WARNING: Propane boilers only
Gas Odor Inspection
Smell near the floor for the gas odorant or any unusual odor
Is there any unusual odor detected near the floor?
Gas Leak Precautions
Is a qualified service technician present to light the propane burner?
Check for flame outages or pilot outages
Are flame outages or pilot outages common?
Gas Odorant Level Check
Access the parts list for your equipment in MaintainX.
Front Section
315-700-100
Intermediate Section, Regular
315-700-120
Intermediate Section With Special Side Tappings
315-700-130
Intermediate Section, Supply (Steam Boilers)
315-700-150
Intermediate Section, Tankless
315-700-140
Front Section
315-700-100
Intermediate Section, Regular
315-700-120
Intermediate Section With Special Side Tappings
315-700-130
Intermediate Section, Supply (Steam Boilers)
315-700-150
Intermediate Section, Tankless
315-700-140
Front Section
315-700-100
Intermediate Section, Regular
315-700-120
Intermediate Section With Special Side Tappings
315-700-130
Intermediate Section, Supply (Steam Boilers)
315-700-150
Intermediate Section, Tankless
315-700-140
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













