MaintainX Asset Hub logo
EnterprisePricing
Trane

Trane Modular Air Handler M-Series ТЕМ6АОВЗОН

Need answers fast?
Explore the manual using AI.

Trane Modular Air Handler M-Series ТЕМ6АОВЗОН
Trane Modular Air Handler M-Series ТЕМ6АОВЗОН

The Trane Modular Air Handler M-Series TEM6AOVZON is a high-performance air handling unit designed for efficient climate control in commercial settings. This versatile model offers customizable configurations and reliable operation, ensuring optimal indoor air quality and comfort. Ideal for various applications, it combines advanced technology with robust construction for long-lasting performance.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Trane Modular Air Handler M-Series ТЕМ6АОВЗОН

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Trane Modular Air Handler M-Series ТЕМ6АОВЗОН

Trane Modular Air Handler M-Series ТЕМ6АОВЗОН

Create an account to install this asset package.

Maintenance Plans for Trane Modular Air Handler Model M-Series ТЕМ6АОВЗОН

Integrate maintenance plans directly into your work orders in MaintainX.

1 Monthly Air Handler Maintenance

Check mark

WARNING: Hazardous Service Procedures! The maintenance and troubleshooting procedures recommended in this section of the manual could result in exposure to electrical, mechanical or other potential safety hazards. Always refer to the safety warnings provided throughout this manual concerning these procedures.

Check mark

WARNING: Rotating Components! Disconnect all electric power, including remote disconnects before servicing. Follow proper lockout/ tagout procedures to ensure the power can not be inadvertently energized. Secure drive sheaves to ensure rotor cannot freewheel.

Check mark

Clean or replace air filters if clogged or dirty

Check mark

Coat permanent filters with oil after cleaning

Check mark

Change bag filters when pressure drop is 1 in. wg

Check mark

Relubricate fan bearings if necessary

Check mark

Check and adjust fan belt tension

Check mark

Sign off on the monthly air handler maintenance

Run this procedureArrow right

1 Monthly Cartridge or Bag Relacement

Check mark

Warning: Disconnect all electrical power to the unit before starting

Check mark

Electrical power disconnected

Check mark

Dirty filters and block-offs removed

Check mark

New bag filters slid into the filter rack

Check mark

Note: The pleats should be in the vertical position

Check mark

Optional pre-filters replaced on the appropriate filter rack

Check mark

Fixed block-offs slid into the filter track before the adjustable block-off

Check mark

Note: The adjustable block-off should always be installed last, next to the access door

Check mark

Access door closed and secured

Run this procedureArrow right

1 Monthly Fan Bearing Lubrication

Check mark

CAUTION: Bearing Failure! Do not mix greases with different bases within the bearing. Mixing grease within the bearing may result in premature bearing failure

Check mark

Align bearing set screws

Check mark

Table 19 on page 58 provides bearing set screw torque measurements

Check mark

Ensure the grease used in electric motor bearings is not mixed with the grease used in fan bearings

Check mark

See Table 21 for compatible greases and Table 22 for maximum grease capacity

Check mark

Lubricate the bearing according to the motor manufacturer's recommendations and use the manufacturer-recommended grease

Check mark

Refer to Table 23 for minimum torque of motor mounting and bearings bolts

Check mark

Ensure fan bearings without lubrication lines are sealed bearings

Check mark

Ensure fan bearings equipped with lubrication lines are lubricated with a lithium-based grease that conforms to NLGI No. 2 for consistency

Run this procedureArrow right

1 Monthly Filter Service

Check mark

- Replace Throwaway Filters

Check mark

1. To replace throwaway filters, install new filters with the directional arrows pointing in the direction of airflow

Check mark

Note: Bag and cartridge filters must have an airtight seal to prevent air bypass. If using other than Trane- supplied filters, apply foam gasketing to the vertical edges of the filter. Permanent Filters - Clean permanent filters

Check mark

1 Disconnect all electrical power to the unit

Check mark

2 Wash the filter under a stream of water to remove dirt and lint

Check mark

3 Remove oil from the filter with a wash of mild alkali solution

Check mark

4 Rinse the filter in clean, hot water and allow to dry

Check mark

5 Coat both sides of the filter by immersing or spraying it with Air Maze Filter Lote W or an equivalent

Check mark

6 Allow to drain and dry for about 12 hours

Run this procedureArrow right

1 Yearly Air Handler Maintenance

Check mark

Inspect the unit casing for corrosion. If damage is found, clean and repaint the surface with a rust-resistant primer and vinyl chlorinated lacquer

Check mark

Clean the fan wheels and fan shaft

Check mark

Inspect and clean drain pans

Check mark

Check damper linkages, set screws, and blade adjustment. Clean, but do not lubricate, the nylon damper rod bushings

Check mark

Clean damper operators

Check mark

Inspect electrical components and insulation

Check mark

Inspect wiring for damage

Check mark

Rotate the fan wheel and check for obstructions in the fan housing. The wheel should not rub on the fan housing. Adjust the center if necessary and tighten wheel set screws to the proper torque

Check mark

Lubricate motor bearings in accordance with motor manufacturer’s recommendations

Run this procedureArrow right

Parts for Trane Modular Air Handler M-Series ТЕМ6АОВЗОН

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Bearing Bracket Assembly

BRK1756

Bolt, 1/2-in.

SCR00011

Center Bracket

BRK01418

Clip

CLP0312

Complete Kit

DMP0670

Bearing Bracket Assembly

BRK1756

Bolt, 1/2-in.

SCR00011

Center Bracket

BRK01418

Clip

CLP0312

Complete Kit

DMP0670

Bearing Bracket Assembly

BRK1756

Bolt, 1/2-in.

SCR00011

Center Bracket

BRK01418

Clip

CLP0312

Complete Kit

DMP0670

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Trane

Explore Other Assets