The AO Smith Commercial Gas Water Heater BTL-120 is a robust and efficient solution for high-demand hot water applications. Designed for commercial use, this model ensures reliable performance and longevity, making it ideal for various industrial settings.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

A.O. Smith Commercial Gas Water Heater BTL-120
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Monthly Tank Cleanout Procedure
The following practices will ensure longer life and enable the unit to operate at its designed efficiency:
1. Once a month the heater should be flushed. Open the drain valve and allow two gallons of water to drain from the heater. Inlet water valve should remain open to maintain pressure in tank.
2. A cleanout opening is provided for periodic cleaning of the tank. Gas must be shut off and heater drained before opening cleanout.
To clean heater through cleanout opening, proceed as follows:
3. Drain heater.
4. Remove outer cover plate from lower side of heater jacket.
5. Remove six (6) hex head screws securing tank cleanout plate and remove plate.
6. Remove lime, scale, or sediment using care not to damage the glass lining.
7. Inspect cleanout plate gasket, if new gasket is required, see replacement parts list for item number.
1 Yearly Anode Rod Inspection
CAUTION! Property Damage Hazard
Avoid water heater damage.
Inspection and replacement of anode rod required.
The anode rod is used to protect the tank from corrosion.
Anode rod deterioration depends on water conductivity, not necessarily water condition.
Inspection should be conducted by a qualified technician, and at a minimum should be checked annually after warranty period.
Artificially softened water is exceedingly corrosive because the process substitutes sodium ions for magnesium and calcium ions.
The anode rod should be inspected after a maximum of three years and annually thereafter until condition of anode rod dictates its replacement.
Anode rod intact?
6 Monthly Intake Air Screen Inspection
Warning: This inspection requires trained personnel with PPE!
Is the intake air screen attached to the inlet end of the combustion blower?
Inspect the intake air screen
Is the intake air screen clean of any buildup of debris or foreign material?
Sign off on the intake air screen inspection
6 Monthly Temperature-Pressure Relief Valve
DANGER! Burn hazard. Hot water discharge. Keep clear of Temperature-Pressure Relief Valve discharge outlet.
It is recommended that the Temperature-Pressure Relief Valve should be checked to ensure that it is in operating condition every 6 months.
When checking the Temperature-Pressure Relief Valve operation, make sure that (1) no one is in front of or around outlet of Temperature-Pressure Relief Valve discharge line, and (2) that water discharge will not cause any property damage, as water may be extremely hot. Use care when operating valve as valve may be hot.
Check the pressure relief valve, lift lever at the end of valve several times. The valve should seat properly and operate freely.
If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water heater and drain the water heater. Replace the Temperature-Pressure Relief Valve with a properly rated/sized new one.
If the Temperature-Pressure Relief Valve on water heater weeps or discharges periodically, this may be due to thermal expansion.
NOTE: Excessive water pressure is the most common cause of Temperature-Pressure Relief Valve leakage. Excessive water system pressure is most often caused by 'thermal expansion' in a 'closed system.' The Temperature-Pressure Relief Valve is not intended for the constant relief of thermal expansion.
Temperature-Pressure Relief Valve leakage due to pressure build up in a closed system that does not have a thermal expansion tank installed is not covered under the limited warranty. Thermal expansion tanks must be installed on all closed water systems.
DO NOT PLUG THE TEMPERATURE-PRESSURE RELIEF VALVE OPENING. THIS CAN CAUSE PROPERTY DAMAGE, SERIOUS INJURY OR DEATH.
6 Monthly Water Heater Storage Tank Draining
Turn off the electrical supply to the water heater
Turn off the gas supply at the Main Gas Shutoff Valve if the water heater is going to be shut down for an extended period
Ensure the cold water inlet valve is open
Open a nearby hot water faucet and let the water run until the water is no longer hot
Close the cold water inlet valve to the water heater
Connect a hose to the water heater drain valve and terminate it to an adequate drain
Open the water heater drain valve and allow all the water to drain from the storage tank
Close the water heater drain valve when all water in the storage tank has drained
Close the hot water faucet opened in Step 4
Access the parts list for your equipment in MaintainX.
Cover Gasket
9004099215
NSF Leg Kit
9008883005
UN•LIME 1 gallon
900541610
UN•LIME 5 gallon
9005417105
Cover Gasket
9004099215
NSF Leg Kit
9008883005
UN•LIME 1 gallon
900541610
UN•LIME 5 gallon
9005417105
Cover Gasket
9004099215
NSF Leg Kit
9008883005
UN•LIME 1 gallon
900541610
UN•LIME 5 gallon
9005417105
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX