MaintainX Asset Hub logo
EnterprisePricing
Stryker

Stryker Performance-Load Cot Fastener System 6392

Need answers fast?
Explore the manual using AI.

Stryker Performance-Load Cot Fastener System 6392
Stryker Performance-Load Cot Fastener System 6392

The Stryker Performance-Load Cot Fastener System 6392 is a high-quality, durable cot designed for efficient patient transport in medical environments. This advanced system ensures safety and reliability, making it an essential asset for healthcare facilities. Regular maintenance and proper care are crucial for optimal performance.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Stryker Performance-Load Cot Fastener System 6392

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Stryker Performance-Load Cot Fastener System 6392

Stryker Performance-Load Cot Fastener System 6392

Create an account to install this asset package.

Maintenance Plans for Stryker Performance-Load Cot Fastener System Model 6392

Integrate maintenance plans directly into your work orders in MaintainX.

1 Month Performance-Load Cot Fastener System Maintenance

Check mark

Warning: Service only by qualified personnel

Check mark

Remove product from service before you perform the preventive maintenance inspection

Check mark

Foot end interface check

Check mark

Head end interface check

Check mark

Upload a photo of the cleaned area

Check mark

Sign off on the maintenance activity

Run this procedureArrow right

1 Year Performance-Load Cot Fastener System Maintenance

Check mark

Warning: Service only by qualified personnel

Check mark

Remove product from service before you perform the preventive maintenance inspection

Check mark

Established and followed a maintenance schedule

Check mark

Kept records of the maintenance activity

Check mark

Need to perform preventive maintenance checks more often based on your level of product usage?

Check mark

Check all parts

Check mark

Replaced any worn parts, if necessary

Check mark

Checked full functionality

Check mark

Sign off on the maintenance

Run this procedureArrow right

3 Month Performance-Load Cot Fastener System Maintenance

Check mark

Warning: Service only by qualified personnel

Check mark

Remove product from service before performing the preventive maintenance inspection

Check mark

Check loose fasteners – Replace if loose

Check mark

Record of the maintenance activity

Check mark

Sign off on the maintenance

Run this procedureArrow right

Cleaning and Disinfecting Performance-Load Cot Fastener System with Wipes

Check mark

Cleaning Procedure

Check mark

Wipe external surfaces with a fresh, clean wipe to remove all visible soils

Check mark

Number of wipes used for cleaning

Check mark

Disinfection Procedure

Check mark

Wipe external surfaces with a fresh, clean wipe until wet

Check mark

Enter the time in minutes the external surface remained wet

Check mark

Allow the product to dry before you return it to service

Check mark

Sign off on the cleaning and disinfecting procedure

Run this procedureArrow right

Foot End Cover Assembly Replacement

Check mark

Tools required: T27 Torx driver, 15/16'' hex wrench, 3/8'' Allen wrench

Check mark

Remove and save the four socket head cap screws that secure the foot end cover assembly to the transfer using a T27 Torx driver

Check mark

Remove and save the two button head cap screws that secure the foot end cover assembly to the foot end nose assembly using a T27 Torx driver

Check mark

Remove the foot end cover assembly by sliding it toward the head end of the vehicle patient compartment

Check mark

Reinstall the foot end cover assembly by reversing steps 1-3

Check mark

Loosen the locknut that secures the pin to the head end forging assembly using a 15/16'' hex wrench

Check mark

Adjust the pin so there is maximum clearance between the foot end cover assembly during loading and unloading using a 3/8'' Allen wrench

Check mark

NOTE! The pin must lock into the head end of the fastener while loaded

Check mark

Tighten the locknut that secures the pin to the head end forging assembly using a 15/16'' hex wrench

Run this procedureArrow right

Parts for Stryker Performance-Load Cot Fastener System 6392

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Anchor Primary Coil

6390-001-133

Assembly, Foot End Cover

6392-001-021

Button Head Cap Screw

0004-376-000

Button Head Cap Screw

0004-589-000

Button Head Cap Screw

0004-589-000

Anchor Primary Coil

6390-001-133

Assembly, Foot End Cover

6392-001-021

Button Head Cap Screw

0004-376-000

Button Head Cap Screw

0004-589-000

Button Head Cap Screw

0004-589-000

Anchor Primary Coil

6390-001-133

Assembly, Foot End Cover

6392-001-021

Button Head Cap Screw

0004-376-000

Button Head Cap Screw

0004-589-000

Button Head Cap Screw

0004-589-000

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Stryker

Explore Other Assets