MaintainX, an Autodesk company
EnterprisePricing
Rite-Hite

Rite-Hite Loading Dock Leveler HQ1787 STL

Need answers fast?
Explore the manual using AI.

Rite-Hite Loading Dock Leveler HQ1787 STL
Rite-Hite Loading Dock Leveler HQ1787 STL

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Rite-Hite Loading Dock Leveler HQ1787 STL

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Rite-Hite Loading Dock Leveler HQ1787 STL

Rite-Hite Loading Dock Leveler HQ1787 STL

Create an account to install this asset package.

Maintenance Plans for Rite-Hite Loading Dock Leveler Model HQ1787 STL

Integrate maintenance plans directly into your work orders in MaintainX.

Sequence Valve Adjustment

Check mark

Safety Precautions

Check mark

Ensure no one is standing on or in front of the lip.

Check mark

Engage and secure the SAFE-T-STRUT™ before going under the hydraulic leveler platform or lip.

Check mark

Confirm that the leveler power is locked out and tagged out according to OSHA regulations and approved local codes.

Check mark

Pre-Adjustment Checks

Check mark

Has the unit been run several times in extremely cold temperatures to confirm that the velocity fuse does not lock-up?

Check mark

Check and record the oil level before making any adjustments.

Check mark

Sequence Valve Adjustment - High Setting

Check mark

Is the leveler fully raised and the lip not extending?

Run this procedureArrow right

Shuttle Valve Adjustment

Check mark

Safety Precautions

Check mark

Ensure no one is standing on or in front of the lip.

Check mark

Engage and secure the SAFE-T-STRUT™ before going under the hydraulic leveler platform or lip.

Check mark

Confirm that the leveler power is locked out and tagged out according to OSHA regulations and approved local codes.

Check mark

Pre-Adjustment Considerations

Check mark

Is the temperature below freezing (32°F)?

Check mark

Run the unit several times (5 to 10 cycles) to confirm that the velocity fuse does not lock-up with warmer oil.

Check mark

Shuttle Valve Adjustment

Check mark

Measure the time for the leveler to lower from full raised position with lip extended to the header stops (in seconds).

Run this procedureArrow right

Hydraulic Oil Level Check

Check mark

Safety Precautions

Check mark

Engage and secure the SAFE-T-STRUT™

Check mark

Hydraulic Oil Level Inspection

Check mark

Mechanically raise the leveler

Check mark

Check the hydraulic oil fill level decal on the tank

Check mark

Oil Addition

Check mark

Is additional hydraulic oil needed?

Check mark

Add hydraulic oil if necessary

Run this procedureArrow right

360 Daily Loading Dock Leveler Maintenance

Check mark

Perform Daily and 90-Day Maintenance

Check mark

Perform daily maintenance tasks

Check mark

Perform 90-day maintenance tasks if due

Check mark

Check and tighten control box mounting hardware

Check mark

Retorque all shoulder bolts on SAFE-T-LlP®

Run this procedureArrow right

90 Daily Loading Dock Leveler Maintenance

Check mark

Daily Maintenance

Check mark

Perform all Daily Maintenance

Check mark

Cleaning and Lubrication

Check mark

Clean pit

Check mark

Lubricate the unit with the proper lubricants

Check mark

Lubricate lip and main cylinder clevis pins

Check mark

Structural and Component Inspection

Check mark

Inspect structure, hinge pins, clevis pins and cotter pins for abnormal wear

Check mark

Inspect all conduit, boxes and electrical connections for damage

Run this procedureArrow right

Parts for Rite-Hite Loading Dock Leveler HQ1787 STL

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Lip Plate, SAFE-T-LIP® 6' Wide

19648

Shoulder Bolt

58085

Grease Fitting

51169

Hinge Module, Standard

19543

Hinge Module, Center

19541

Lip Plate, SAFE-T-LIP® 6' Wide

19648

Shoulder Bolt

58085

Grease Fitting

51169

Hinge Module, Standard

19543

Hinge Module, Center

19541

Lip Plate, SAFE-T-LIP® 6' Wide

19648

Shoulder Bolt

58085

Grease Fitting

51169

Hinge Module, Standard

19543

Hinge Module, Center

19541

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Rite-Hite

Explore Other Assets