Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Rite-Hite High Speed Door Fastrax LD
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
12 Monthly High Speed Door Maintenance
Controls/Wiring: Clean and check all connections with disconnect off. Make sure all wires are free from moving parts.
Door Assembly: Perform visual inspection for damage. Tighten all hardware. Replace any worn labels. Use air hose to remove dust and debris.
Door Operation: Operate door and make sure all operations are functioning properly
Drive Tube: Verify drive tube gear is centered over track groove. Make sure bearing set screws and mounting bolts are tight.
Gearbox: Check gearbox fluid level; fill with Mobil - SHC 624 or Phillips 66 - Syncon 32
if low Check lock collar set screws.
Encoder/Chain/Sprockets: Verify encoder chain and sprocket set screws are tight. Verify lock collar on encoder is tight. Check open and close positions adjust as required.
FSTXLD/FSTXFRLD: Verify torque arm bolts are tight.
Lintel Seal (not on FR): Verify lintel seal is sealing wall properly.
1 Monthly Operation Verification
Warning: Only Rite‑Hite authorized service technicians should change the programming.
NOTE: Advise pedestrians to use man doors if present and not to lean into the door way.
Open the control box and verify the state of the green Input LEDs on the i‑COMM 3
Pillow block bearing set screws tightened to 66 to 80in/lb [7.5Nm]
Wires are connected for the photoeyes
All loose wires are secured away from moving parts
Press the “OPEN” button, the door should open and close automatically after a short delay
Observe the door opening to make sure that it fully opens
Observe the closing action to make sure that the door operates smoothly, and fully closes without excessive curtain ripple
6 Monthly High Speed Door Maintenance
Curtain Fans (Optional): Verify that curtain fans are powered and working. Make sure that the fans are positioned properly and are removing condensation from the curtain.
Auto Re‑Feed: Verify auto re‑feed is operational.
Curtain: Inspect for wear or damage; patch immediately to prevent condensation or frost buildup. Clean with warm soapy water. Check drive spheres; if missing or damaged, replace. Check top roller.
Perimeter Seal (FR): Free of tears and providing an adequate seal against curtain and the wall. If torn, patch immediately to prevent condensation build‑up.
Vision (not on FR): Inspect vision for tears or separation. Clean with warm soapy water.
Radial and Track Lubrication: Lubrication of radials and tracks may be required more than every 6 months, based on usage and environmental conditions.
Lubrication of the radials and tracks is the sole responsibility of the end user. If door is mounted in a dirty environment, it may be required to remove the existing grease prior to adding new.;
Drive Sphere Replacement
Warning: This procedure requires trained personnel with PPE!
Type of adhesive used
Adhesive applied to curtain edge drive sphere stud
Adhesive applied to stud before tightening
Adhesive oozed out both sides after stud is tightened
Stud tightened prior to adhesive starting to dry
Adhesive dry time in minutes
Torque spec in in-lbs
Sign off on the drive sphere replacement
Encoder Replacement
Unscrew connector
Loosen lock collar (C) using 2mm Allen wrench and slide encoder off of shaft (A)
Install new encoder, tighten lock collar (14in-lb. [1.5Nm]), line up notch and screw connector
Proceed to 'Limit (Encoder) Set-up' on page 68
Sign off on the encoder replacement
Access the parts list for your equipment in MaintainX.
575V 3Ph Curtain Fan
13250090
Adapter, Rs-485, M Series
10300019
Aero Lubriplate
54650001
Bearing, Flange, 1In Bore
12500034
Block,Mnt,Nord Arm,Dfndr
13000065
575V 3Ph Curtain Fan
13250090
Adapter, Rs-485, M Series
10300019
Aero Lubriplate
54650001
Bearing, Flange, 1In Bore
12500034
Block,Mnt,Nord Arm,Dfndr
13000065
575V 3Ph Curtain Fan
13250090
Adapter, Rs-485, M Series
10300019
Aero Lubriplate
54650001
Bearing, Flange, 1In Bore
12500034
Block,Mnt,Nord Arm,Dfndr
13000065
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX