MaintainX Asset Hub logo
EnterprisePricing
Liebherr

Liebherr Commercial Freezer BGPv 6520

Need answers fast?
Explore the manual using AI.

Liebherr Commercial Freezer BGPv 6520
Liebherr Commercial Freezer BGPv 6520

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Liebherr Commercial Freezer BGPv 6520

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Liebherr Commercial Freezer BGPv 6520

Liebherr Commercial Freezer BGPv 6520

Create an account to install this asset package.

Maintenance Plans for Liebherr Commercial Freezer Model BGPv 6520

Integrate maintenance plans directly into your work orders in MaintainX.

6 Monthly Dust Collector Cleaning

Check mark

Warning: Ensure the dust collector is unplugged before starting the cleaning process.

Check mark

Dust filter removed by lifting upwards

Check mark

Dust filter cleaned with water and detergent

Check mark

Dust filter reinstalled

Check mark

Sign off on the dust collector cleaning

Run this procedureArrow right

Alarm Test

Check mark

This test checks the function of the internal and any external connected alarm device. The appliance does not stop its refrigerating function during this test.

Check mark

Press bell + arrow down for 5 seconds.

Check mark

Enter the displayed temperature value

Check mark

Check if the temperature value is rising by 0.1°C every 2 seconds.

Check mark

Check if the upper alarm limit symbol appears in the display when the upper alarm limit is reached.

Check mark

Check if an external alarm unit connected to the floating alarm output is activated.

Check mark

Check if the temperature value continues to rise up to 0.2°C above the upper alarm limit.

Check mark

Check if the same process takes place automatically for the lower alarm limit.

Check mark

Check if the lower alarm limit symbol appears in the display.

Run this procedureArrow right

Freezer Water Drain

Check mark

Warning: Ensure the freezer is unplugged before starting the procedure

Check mark

Is the drain hose with an R 3/4 connection fitted to the underside of the appliance?

Check mark

Is the water collected in the interior during cleaning being drained off?

Check mark

Upload a photo of the fitted drain hose

Check mark

Sign off on the freezer water drain cleaning

Run this procedureArrow right

Freezer Cleaning

Check mark

WARNING: Before cleaning, always disconnect the appliance from the mains. Pull out the plug or switch off the fuse.

Check mark

CAUTION: Risk of damage to the appliance components and risk of injury due to hot steam. Do not use steam cleaning equipment to clean the appliance.

Check mark

Appliance disconnected from the mains?

Check mark

Steam cleaning equipment not used?

Check mark

Cleaning agent used

Check mark

No cleaning water penetrated into the electrical components?

Check mark

All parts dried well with a cloth?

Check mark

Used a commercially available stainless-steel cleaning agent for stainless-steel appliances?

Check mark

Type plate on the inside of the appliance not damaged or removed?

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Liebherr

Explore Other Assets