Ingersoll Rand Compressor N160K Single Stage
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Compressor Maintenance
Air Filter Maintenance
Check and replace air filter if needed
Scavenge screen - Check / clean
2 Yearly Coolant Hoses Replacement
Inspection and Preparation
Inspect coolant hoses for brittleness or damage
Is hose replacement needed?
Coolant Draining
Drain coolant into a clean container
Cover the container to prevent contamination
Hose Replacement
Remove the old hose
Install the new hose
500 Hourly Compressor Maintenance
Check that all components are in place
Cleaning and Maintenance
Clean the Cooler Core(s)
Clean the Moisture separator
Clean the Motor cowl
Coolant Analysis
Was the Food Grade Coolant analyzed?
Describe the results of the coolant analysis
Initial 150 Hours Coolant Filter Replacement
Coolant Filter Change
Loosen filter element with the correct tool
Remove the element from the housing
Place the old element in a sealed bag and dispose of in a safe way
Clean the mating face of the housing
Remove the new Ingersoll Rand replacement element from its protective package
Apply a small amount of coolant to the element seal
Screw the new element down until the seal makes contact with the housing, then hand tighten a further half turn
Post Replacement Checks
2000 Hourly Compressor Replacement
Coolant Filter Replacement
Loosen filter element with the correct tool.
Remove the element from the housing.
Place the old element in a sealed bag and dispose of in a safe way.
Clean the mating face of the housing.
Remove the new Ingersoll Rand replacement element from its protective package.
Apply a small amount of coolant to the element seal.
Screw the new element down until the seal makes contact with the housing, then hand tighten a further half turn.
Post Replacement Check
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX