MaintainX Asset Hub logo
EnterprisePricing
Honeywell

Honeywell Electronic Air Cleaner F300A 20x25

Need answers fast?
Explore the manual using AI.

Honeywell Electronic Air Cleaner F300A 20x25
Honeywell Electronic Air Cleaner F300A 20x25

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Honeywell Electronic Air Cleaner F300A 20x25

Honeywell Electronic Air Cleaner F300A 20x25

Create an account to install this asset package.

Maintenance Plans for Honeywell Electronic Air Cleaner Model F300A 20x25

Integrate maintenance plans directly into your work orders in MaintainX.

6 Monthly Prefilters Replacement

Check mark

To assure optimum performance from the air cleaner, the cells and prefilters must be cleaned regularly and the postfilters replaced regularly—twice a year with normal use or more frequently with heavy use.

Check mark

Washing frequency varies, depending on the number of family members, pets, activities (such as cooking or woodworking) and smoking habits.

Check mark

NOTE: To let the heating or air conditioning system operate normally while the cells are being washed, simply turn off the air cleaner switch.

Check mark

Cleaning your Prefilter

Check mark

1. The quickest and easiest way to clean your prefilter is to use the brush attachment of your vacuum cleaner to vacuum the lint off the dirty side of the prefilter.

Check mark

Greasy dirt may require soaking the prefilter in a tub or rinsing with the garden hose. Do not wash the prefilter in the dishwasher or car wash.

Check mark

2. The prefilter should be cleaned every 6 months or more frequently with heavy use. This will keep the prefilter clean of air choking lint that can make your system work harder.

Check mark

Cleaning your Cells • A quick cleaning of the cells can be done by simply wiping down the ionizer wires with a damp cloth. This will help boost the efficiency of the air cleaner between full cleaning cycles. This quick clean can be done every time the prefilters are cleaned.

Check mark

• A full cleaning of the cells will return the air cleaner to its peak efficiency. An easy way to wash the cells is in a tub of hot, soapy water. Just soak the cells until the water cools, agitate and rinse.

Run this procedureArrow right

1 Yearly Air Cleaner Cleaning

Check mark

Warning: This cleaning procedure requires trained personnel with PPE!

Check mark

Pressure drop across the air cleaner

Check mark

Is the pressure drop across the air cleaner reaches 0.5 in. w.c. (0.1 kPa)?

Check mark

If the air cleaner is installed downstream from an atomizing humidifier or if the installation includes both heating and cooling, more frequent replacement may be necessary.

Check mark

Is the air cleaner installed downstream from an atomizing humidifier or if the installation includes both heating and cooling?

Check mark

Clogged prefilters must be cleaned promptly to avoid restricting airflow and reducing efficiency of the heatingcooling system.

Check mark

Are the prefilters clogged?

Check mark

Record the maintenance date in the space provided on the Electronic Air Cleaner Wash Reminder and Postfilter Replacement Schedule.

Check mark

Sign off on the air cleaner cleaning

Run this procedureArrow right

Ionizer Wires Replacement

Check mark

Replacing Ionizer Wires

Check mark

Broken or bent ionizer wires can cause an electrical short to ground, often resulting in visible arcing or sparking.

Check mark

Do not use cells until broken wires are removed.

Check mark

Cells can be used temporarily with one wire missing, but replace the wire as soon as possible.

Check mark

Replacement wires are supplied cut to length with eyelets on both ends for easy installation.; To install:

Check mark

1. Hook the eyelet on one end of the wire over the spring connector on one end of the cell.

Check mark

Be careful to avoid damaging spring connectors or other parts of the cells.

Check mark

2. Hold the opposite eyelet with a needle nose pliers and stretch the wire the length of the cell.

Check mark

Depress the opposite spring connector and hook the eyelet over it.

Run this procedureArrow right

Reduce Ozon Odor Modification

Check mark

CAUTION

Check mark

Electric Shock Hazard.

Check mark

Can cause personal injury.

Check mark

Always disconnect power and open access door before opening power supply cover.

Check mark

The electronic air cleaner generates a small amount of ozone in normal operation.

Check mark

During the first week or two of operation, the amount may be higher because of sharp edges on some of the new high voltage metal parts.

Check mark

Normal use quickly dulls these edges.

Check mark

If desired, the ozone generated by the air cleaner can be reduced in one of two ways:

Check mark

1. Install an activated carbon filter downstream from the air cleaner. Make sure particles from the air filter cannot fall into the air cleaner.

Run this procedureArrow right

Air Cleaner Operation Check

Check mark

Is the air cleaner switch turned on and system blower energized?

Check mark

The neon light next to the On-Off switch is on

Check mark

The neon light goes off after the system blower is turned off

Check mark

A snapping sound is heard when the test button is pushed with the air cleaner energized

Check mark

The above steps are repeated for each fan speed with the same results

Check mark

Sign off on the air cleaner operation check

Run this procedureArrow right

Parts for Honeywell Electronic Air Cleaner F300A 20x25

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

F300 Door Includes No. 2

32007528-003

Test Button Assembly

137980A

Electronic Cell

FC37A1064

Cell Handle

137266

Prefilter (Without Spring Clips)

203372

F300 Door Includes No. 2

32007528-003

Test Button Assembly

137980A

Electronic Cell

FC37A1064

Cell Handle

137266

Prefilter (Without Spring Clips)

203372

F300 Door Includes No. 2

32007528-003

Test Button Assembly

137980A

Electronic Cell

FC37A1064

Cell Handle

137266

Prefilter (Without Spring Clips)

203372

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Honeywell

Explore Other Assets