

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Goodman Gas Furnace AMSS921205DNAA
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Burner Visual Check
HIGH VOLTAGE WARNING
Turn the furnace on at the thermostat
Wait a few minutes for dust to settle
Check the burner flames for the following characteristics
Are the flames stable, quiet, soft and blue with slightly orange tips?
Do the flames extend directly outward from the burner ports without curling downward, floating or lifting off the ports?
Electronic Air Cleaner Inspection
Pre-Inspection Setup
Ensure the air cleaner is installed in the correct position
Is the air cleaner readily accessible for inspection?
Electronic Air Cleaner Inspection
Inspect and clean the following components
Media Air Cleaner Inspection
Inspect and replace the Media Air Cleaner filter cartridge if necessary
Check availability of Carbon Filters
Post-Inspection
2 Monthly Filter Replacement
WARNING: High Voltage
Disconnect all power sources
Check filter type
Clean the permanent filter
Replace the disposable filter
Verify filter installation
Reconnect all power sources
Check system performance
Pressure Regulator Adjustment
Safety Precautions
Connect a manometer to the outlet tap at the gas valve before adjusting the pressure regulator.
Pressure Regulator Adjustment
Record the initial manifold pressure in inches of water column.
Is the manifold pressure within the acceptable range for natural gas (3.5 inches water column ± 3 inches) or propane gas (10 inches water column ± 3 inches)?
Select the type of gas used.
Adjust the pressure regulator on the gas valve by turning clockwise to increase pressure and counterclockwise to decrease pressure.
Record the adjusted manifold pressure in inches of water column.
Propane Gas Specific Instructions
1 Yearly Furnace Inspection
WARNING: HIGH VOLTAGE
Disconnect all power before servicing or installing the unit
Check the following furnace components for proper working order
Ignitor Handling Precautions
Ensure ignitor is handled with care, avoiding contact with bare fingers and rough handling
Post Inspection
Were any repairs or services necessary?
Describe any repairs or services performed
Technician's Signature
Access the parts list for your equipment in MaintainX.
External Filter Rack Kit
EFR02
Electronic Air Cleaner
GSAS
Electronic Air Cleaner
ASAS
Media Air Cleaner
GMU
Media Air Cleaner
AMU
External Filter Rack Kit
EFR02
Electronic Air Cleaner
GSAS
Electronic Air Cleaner
ASAS
Media Air Cleaner
GMU
Media Air Cleaner
AMU
External Filter Rack Kit
EFR02
Electronic Air Cleaner
GSAS
Electronic Air Cleaner
ASAS
Media Air Cleaner
GMU
Media Air Cleaner
AMU
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













