

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Goodman Gas Furnace AMSS920805CNAA
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Pressure Regulator Adjustment
Safety Precautions
Connect a monometer to the outlet tap at the gas valve before adjusting the pressure regulator.
Pressure Regulator Adjustment
Record the initial manifold pressure reading.
Is the manifold pressure within the acceptable range (3.5 inches water column for natural gas or 10 inches water column for propane gas)?
Adjust the pressure regulator direction
Record the final manifold pressure reading after adjustment.
Propane Gas Specific Instructions
Ensure no unit gas valve regulator is used for propane gas.
Burner Visual Check
Safety Warning
Turn on the furnace at the thermostat
Wait a few minutes for dust to settle
Check the burner flames for the following characteristics
Are the flames stable, quiet, soft and blue with slightly orange tips?
Are the flames extending directly outward from the burner ports without curling downward, floating or lifting off the ports?
2 Monthly Filter Replacement
WARNING: High Voltage
Disconnect all power sources
Check the type of filter
Clean the permanent filter
Replace the disposable filter
Check that the new or cleaned filter is properly installed
Reconnect all power sources
Verify system operation
Heating Performance Test
Preparation
Ensure all other gas appliances are turned off
Wait for at least fifteen minutes after the heating cycle has started
Gas Meter Reading
Clock the gas meter to determine the time for one complete revolution of the cubic foot dial
Enter the time recorded for one complete revolution (in seconds)
Calculate BTU Input
Enter the calorific value of the gas (BTU per cubic foot)
Calculate the cubic feet of gas consumed per hour
1 Yearly Furnace Inspection
WARNING: HIGH VOLTAGE
Disconnect all power before servicing or installing the unit
Check the following furnace components for proper working order
Ignitor Handling Precautions
Ensure only a qualified servicer handles the ignitor
Was the ignitor handled with care, avoiding bare fingers and rough handling?
Post Inspection Actions
Were all necessary repairs or services performed?
Technician's Signature
Access the parts list for your equipment in MaintainX.
External Filter Rack Kit
EFR02
Electronic Air Cleaner
GSAS
Electronic Air Cleaner
ASAS
Media Air Cleaner
GMU
Media Air Cleaner
AMU
External Filter Rack Kit
EFR02
Electronic Air Cleaner
GSAS
Electronic Air Cleaner
ASAS
Media Air Cleaner
GMU
Media Air Cleaner
AMU
External Filter Rack Kit
EFR02
Electronic Air Cleaner
GSAS
Electronic Air Cleaner
ASAS
Media Air Cleaner
GMU
Media Air Cleaner
AMU
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













