Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Frick Rotary Screw Compressor RWF II 264 SS
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Daily Compressor Unit Check
Maintenance program
Check the compressor unit daily for leaks
Check for abnormal vibration
Check for noise
Check for proper operation
Log any issues found
Initial oil analysis
Vibration analysis
Sign off on the daily compressor unit check
1 Yearly High Pressure Cut-Out Testing
Warning: This procedure requires trained personnel with PPE!
Is the EZ-CAL test block installed on the package?
Is the pressure transducer wired to the Quantum HD controller?
Is the tubing run to the compressor discharge connection?
Is the block locked in the RUN position during normal operation?
EZ-CAL principles of operation
Is the HPCO fully open to the discharge pressure source in the RUN position?
Is the external pressure source connected to the test connection quick connect in the TEST position?
Is the external source connected directly to the HPCO in the TEST position?
1 Yearly VFD Units Skip Frequencies Check
WARNING: Failure to enter skip frequencies could cause catastrophic compressor failure or severe compressor damage and result in serious injury or death.
Check for excess vibration and skip frequencies anytime unit operating conditions change
Enter the VFD speed
Decrease the VFD speed by 100 rpm increments and check the entire package for elevated energy at each stage until the minimum speed range is reached.
Check for high energy hot spots
Enter the vibration meter reading
Any readings that meet or exceed one inch per second must have that frequency range skipped in the microprocessor for the VFD, eliminating the ability of the package to operate within that frequency range.
Enter the identified frequency range to be skipped
Each identified range needs to have the skip set to as narrow a frequency band as possible, only making it wider until full range is accommodated.
200 Hourly Oil Filter Change
Warning: Use of filter elements other than Frick may cause warranty claim to be denied.
Is a single oil filter installed?
If a single oil filter is installed, push [STOP] key on microprocessor panel to shut down unit, then open disconnect switches for compressor and oil pump motor starters.
If dual oil filters are installed, open the outlet, then inlet service valves of the standby filter.
Warning: Open inlet service valve slowly to prevent a sudden pressure drop which could cause an oil filter differential alarm.
Did you close outlet then inlet service valves of filter being serviced?
Did you open bleed valve and purge pressure from the oil filter cartridge?
Notice: Recover or transfer all refrigerant vapor, in accordance with local ordinances, before opening to atmosphere.
Did you remove the plug from the bottom of the filter canister and drain the oil?
200 Hourly Rotary Screw Compressor Check
Check coupling (a)
a. Check bolts, shim packs, center inserts, keys, and all bolt torques.
Check alignment (h)
h. Refer to 070.210-IB for foot mounting alignment.
Suction and discharge flange bolts (d)
d. Verify tightness of bolts on suction and discharge flanges. See Table 13 for torque requirements.
Check electrical connections (b)
b. Check and torque all terminals in the processor and starter panel per the specification posted in the enclosure.
Check sensor calibration (c)
Access the parts list for your equipment in MaintainX.
Frick Optical Isolation Kits
639C0133G01
Oil Analysis Kit
333Q0001853
O-Ring 1 1⁄16-12 UN-2B
980A0012K66
O-Ring 15⁄16-12 UN-2B
980A0012K69
O-Ring 9/16-18 UNF-2B
980A0012K60
Frick Optical Isolation Kits
639C0133G01
Oil Analysis Kit
333Q0001853
O-Ring 1 1⁄16-12 UN-2B
980A0012K66
O-Ring 15⁄16-12 UN-2B
980A0012K69
O-Ring 9/16-18 UNF-2B
980A0012K60
Frick Optical Isolation Kits
639C0133G01
Oil Analysis Kit
333Q0001853
O-Ring 1 1⁄16-12 UN-2B
980A0012K66
O-Ring 15⁄16-12 UN-2B
980A0012K69
O-Ring 9/16-18 UNF-2B
980A0012K60
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX