MaintainX, an Autodesk company
EnterprisePricing
Engineered Air

Engineered Air HVAC Unit HE60

Need answers fast?
Explore the manual using AI.

Engineered Air HVAC Unit HE60
Engineered Air HVAC Unit HE60

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Engineered Air HVAC Unit HE60

Engineered Air HVAC Unit HE60

Create an account to install this asset package.

Maintenance Plans for Engineered Air HVAC Unit Model HE60

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Safety Shutoff Valve Testing

Check mark

Safety Shutoff Valve Leak Test

Check mark

De-energize the control system

Check mark

Close the upstream manual gas valve

Check mark

Connect a ¼” (6mm) tube to the outlet pressure tap on the safety shutoff valve

Check mark

Immerse the opposite end of the ¼” (6mm) tube vertically ½” (13mm) into a clear container of water

Check mark

Count the number of bubbles appearing during a 10 second period

Check mark

Is the bubble rate greater than that noted in the manufacturer’s table?

Check mark

If the bubble rate is greater than noted, choose the action taken

Check mark

If bubble rate is less than noted in the table, remove the ¼” (6mm) tube, reconnect the outlet pressure tap plug

Run this procedureArrow right

Initial 2 Week Set Screw Check

Check mark

Set Screws

Check mark

Check set screws for looseness on the shaft

Check mark

Were any set screws loose?

Check mark

Tighten loose set screws where required

Check mark

Record any issues or observations

Run this procedureArrow right

1 Yearly Burner Inspection

Check mark

Burners

Check mark

Remove any scale from the burner plates

Check mark

Ensure that the holes on the burner plates and gas orifices are clear of foreign material

Check mark

Verify orifice sizes on tee casting

Run this procedureArrow right

1 Weekly Dodge Spherical Roller Solid Pillow Block Lubrication

Check mark

Lubrication of Dodge Fan Bearings — Spherical Roller Bearing, Solid Pillow Block

Check mark

Determine lubrication interval based on shaft diameter and speed (RPM)

Check mark

Is the unit operating 24 hours?

Check mark

Lubricate with multipurpose roller bearing NLGI No. 2

Check mark

Select grease example used

Check mark

Re-lubricate while running until purging occurs at seals

Check mark

Adjust lubrication frequency based on purged grease condition

Check mark

Lubricate bearings prior to extended shutdown or storage

Check mark

Rotate shaft monthly to aid corrosion protection

Run this procedureArrow right

1 Monthly VFD Enclosure Filter Maintenance

Check mark

VFD Enclosure

Check mark

Check the condition of the filters

Check mark

Is the filter due for replacement based on the schedule or condition?

Check mark

Replace the filter if necessary

Check mark

Record the date of filter inspection and replacement in the maintenance log

Run this procedureArrow right

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Engineered Air

Explore Other Assets