Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Engineered Air HVAC Unit HE171/O
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Filter Maintenance
Filters
Determine filter-changing intervals based on
Enter the scheduled interval for filter changes (in months)
Is the unit operating with high levels of outside air?
Is it the economizer season?
Is there heavy frost or snow in the area?
Remove or relocate filters during winter months if necessary
Check for plugged or excessively dirty filters
Record filter quantities, sizes, and types from submittal record
1 Yearly Motor Lubrication
Motor Lubrication
Refer to motor manufacturer for lubrication recommendations
Remove grease drain plugs and operate motor for 15 minutes before replacing plugs
Ensure not to over grease the motor
Select the motor lubrication interval based on service hours per day
Specify greasing instructions for motors running in severe conditions as per manufacturer
1 Yearly Safety Shutoff Valve Testing
Safety Shutoff Valve Leak Test
De-energize the control system.
Close the upstream manual gas valve.
Connect a ¼” (6mm) tube to the outlet pressure tap on the safety shutoff valve.
Immerse the opposite end of the ¼” (6mm) tube vertically ½” (13mm) into a clear container of water.
Count the number of bubbles appearing during a 10 second period.
Is the bubble rate greater than that noted in the manufacturer’s table?
If the bubble rate is greater than noted, choose the action taken
If bubble rate is less than noted in the table, remove the ¼” (6mm) tube, reconnect the outlet pressure tap plug.
6 Monthly Outdoor Air Intake Inspection
Outdoor Air Intakes, Mixing Sections and Dampers
Check cleanliness of outdoor air intakes, screens, and adjacent areas
Inspect integrity of outdoor air intakes, screens, and adjacent areas
Verify proper operation of outdoor air intakes, screens, and adjacent areas
Adjust dampers if required
Initial Start-Up Check
Before Start-Up
Remove tie-down bolts, straps and blocks
Start-Up Check List
Set all associated electrical switches, controls, thermostats and main disconnect switch to 'OFF' position.
Close all manual valves and field piping valves.
Confirm that all shipping materials have been removed.
Check all bearings, drive and fan set screws for tightness.
Check drive alignment and belt tension.
Inspect all electrical wiring for loose connections.
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX