MaintainX Asset Hub logo
EnterprisePricing
Engineered Air

Engineered Air Fan Coil JM

Need answers fast?
Explore the manual using AI.

Engineered Air Fan Coil JM
Engineered Air Fan Coil JM

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Engineered Air Fan Coil JM

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Engineered Air Fan Coil JM

Engineered Air Fan Coil JM

Create an account to install this asset package.

Maintenance Plans for Engineered Air Fan Coil Model JM

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Coil Inspection

Check mark

Inspection and Cleaning

Check mark

Inspect coils and drain pans for cleanliness and biological growth

Check mark

Check for any signs of biological growth on coils and drain pans

Check mark

Clean the external surface of finned coils using a low pressure water spray and a brush

Check mark

Are cleaning additives or solutions compatible with coil materials or coatings?

Check mark

Use a fin comb to straighten any damaged or bent fins

Check mark

Safety and Compliance

Check mark

Is the area safe for inspection and cleaning?

Check mark

Ensure no moisture carry over from dirty coils

Run this procedureArrow right

5 Yearly Belt Drive Motor Lubrication

Check mark

Preparation

Check mark

Remove grease drain plugs from the motor

Check mark

Operate the motor for 15 minutes before replacing plugs

Check mark

Lubrication Guidelines

Check mark

Recommended Motor Lubrication Intervals

Check mark

Note any severe conditions affecting lubrication frequency

Check mark

Post-Lubrication

Check mark

Replace grease drain plugs

Check mark

Ensure no over-greasing has occurred

Run this procedureArrow right

1 Yearly Electric Heater Visual Inspection

Check mark

Safety Precautions

Check mark

Disconnect power before servicing

Check mark

Ensure all interlock and safety switches are engaged

Check mark

Visual Inspection

Check mark

Check for signs of potential problems

Check mark

Is sufficient airflow passing through the heater as marked on the unit rating plate?

Check mark

Are there any areas of the coil elements glowing bright red when viewed in the dark with the unit operating?

Check mark

Post Inspection

Check mark

Reconnect power after servicing

Run this procedureArrow right

Heresite Coating Repair

Check mark

Surface Preparation

Check mark

Ensure surfaces are completely dry

Check mark

Use a nylon brush to remove any loose scale

Check mark

Roughen up areas to be repaired with a wire brush

Check mark

Vacuum fins or the affected area to ensure any loose residue is gone

Check mark

Cleaning

Check mark

Spray or brush Heresite® S-440 solvent (or equivalent cleaner) to dissolve any oils or grease

Check mark

Vacuum the affected area again

Check mark

Allow one hour for the solvent to dissolve completely

Run this procedureArrow right

1 Monthly Filter Replacement

Check mark

Pre-Replacement Inspection

Check mark

Measure the pressure drop across the filter

Check mark

Is the pressure drop within acceptable limits?

Check mark

Filter Replacement

Check mark

Remove filters from units with high levels of outside air during winter months

Check mark

Inspect filters for excessive dirt or plugging

Check mark

Replace filters with same size and type

Check mark

Post-Replacement Procedures

Check mark

Were all local, regional, and national safety and disposal regulations followed?

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Engineered Air

Explore Other Assets