MaintainX Asset Hub logo
EnterprisePricing
ENERSYS

ENERSYS SCR Transformer Type Battery Charger SLTC2

Need answers fast?
Explore the manual using AI.

ENERSYS SCR Transformer Type Battery Charger SLTC2
ENERSYS SCR Transformer Type Battery Charger SLTC2

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for ENERSYS SCR Transformer Type Battery Charger SLTC2

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

ENERSYS SCR Transformer Type Battery Charger SLTC2

ENERSYS SCR Transformer Type Battery Charger SLTC2

Create an account to install this asset package.

Maintenance Plans for ENERSYS SCR Transformer Type Battery Charger Model SLTC2

Integrate maintenance plans directly into your work orders in MaintainX.

PC Boards Replacement

Check mark

Introduction

Check mark

Return all replaced components to your service center.

Check mark

The following sections explain how to replace each component. After replacing a component, be sure to: Reconnect all leads exactly as they were removed, Replace any heat-shrink tubing if any old tubing was removed, Retighten all connections, Replace covers.

Check mark

Preparation

Check mark

Disconnect the battery.

Check mark

Disconnect the AC power.

Check mark

PC BOARD

Check mark

Removal

Check mark

Use an anti-static wrist strap (i.e. EnerSys part number 174-2-1) when handling, removing and replacing circuit board assemblies.

Run this procedureArrow right

Contactor Replacement

Check mark

Introduction

Check mark

Return all replaced components to your service center.

Check mark

The following sections explain how to replace each component. After replacing a component, be sure to:

Check mark

1. Reconnect all leads exactly as they were removed,

Check mark

2. Replace any heat-shrink tubing if any old tubing was removed,

Check mark

3. Retighten all connections

Check mark

4. Replace covers.

Check mark

Preparation

Check mark

Please follow these steps before removing or replacing any component:

Run this procedureArrow right

EPROM Replacement

Check mark

EPROM

Check mark

Please follow these steps before removing or replacing an EPROM:

Check mark

Disconnect the battery.

Check mark

Disconnect the AC power.

Check mark

Removal:

Check mark

Follow these steps to remove the EPROM. (Be sure your hands are fairly clean before touching a PC board.)

Check mark

1. Turn the AC power OFF.

Check mark

2. Unplug the battery.

Check mark

3. Touch your finger to a ground to discharge static.

Run this procedureArrow right

Control Transformer Replacement

Check mark

Introduction

Check mark

Return all replaced components to your service center.

Check mark

The following sections explain how to replace each component. After replacing a component, be sure to:

Check mark

1. Reconnect all leads exactly as they were removed,

Check mark

2. Replace any heat-shrink tubing if any old tubing was removed,

Check mark

3. Retighten all connections

Check mark

4. Replace covers.

Check mark

Preparation

Check mark

Please follow these steps before removing or replacing any component:

Run this procedureArrow right

Contactor Test

Check mark

CONTACTOR (IF AVAILABLE)

Check mark

First Contactor Test

Check mark

Please follow these steps before testing the contactor:

Check mark

Disconnect the battery.

Check mark

On Connector J3, on the PC board,

Check mark

1. Short pins 6 and 7.

Check mark

2. The contactor should pull in.

Check mark

3. If it does not, check the wiring from Connector J3 to the fuse and to the contactor.

Check mark

Second Contactor Test

Run this procedureArrow right

Parts for ENERSYS SCR Transformer Type Battery Charger SLTC2

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

6' of #10AWG AC Cord with 30 AMP Plug.

X225-77-2

6' of #10AWG AC Cord with 30 AMP Plug and 30AMP Receptacle

X225-77-1

Stacking Hardware Kit

X225-99-0-2

Wall Mounting Brackets

X225-99-0-1

Anti-Static Wrist Strap

174-2-1

6' of #10AWG AC Cord with 30 AMP Plug.

X225-77-2

6' of #10AWG AC Cord with 30 AMP Plug and 30AMP Receptacle

X225-77-1

Stacking Hardware Kit

X225-99-0-2

Wall Mounting Brackets

X225-99-0-1

Anti-Static Wrist Strap

174-2-1

6' of #10AWG AC Cord with 30 AMP Plug.

X225-77-2

6' of #10AWG AC Cord with 30 AMP Plug and 30AMP Receptacle

X225-77-1

Stacking Hardware Kit

X225-99-0-2

Wall Mounting Brackets

X225-99-0-1

Anti-Static Wrist Strap

174-2-1

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from ENERSYS

Explore Other Assets