MaintainX, an Autodesk company
EnterprisePricing
Daikin

Daikin Cooling-Only Outdoor Unit RKS60F3V1B9

Need answers fast?
Explore the manual using AI.

Daikin Cooling-Only Outdoor Unit RKS60F3V1B9
Daikin Cooling-Only Outdoor Unit RKS60F3V1B9

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Cooling-Only Outdoor Unit RKS60F3V1B9

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Cooling-Only Outdoor Unit RKS60F3V1B9

Daikin Cooling-Only Outdoor Unit RKS60F3V1B9

Create an account to install this asset package.

Maintenance Plans for Daikin Cooling-Only Outdoor Unit Model RKS60F3V1B9

Integrate maintenance plans directly into your work orders in MaintainX.

Outdoor Fan / Fan Motor Removal

Check mark

Pre-removal Safety

Check mark

Wait for 10 minutes or more after turning off all power supplies before disassembling work.

Check mark

Fan Motor and Outdoor Fan Removal

Check mark

Remove the shield plate.

Check mark

Disconnect the connector [S70] for the fan motor.

Check mark

Release the clamp from the partition plate.

Check mark

Release the fan motor lead wire from the groove and the 2 hooks of the partition plate.

Check mark

Remove the nut and remove the outdoor fan.

Check mark

Remove the 2 screws of the fan motor fixing frame.

Run this procedureArrow right

Four Way Valve / Electronic Expansion Valve Removal

Check mark

Safety Precautions

Check mark

Wait for 10 minutes after turning off all power supplies before starting disassembly.

Check mark

Ensure pipes and parts heated by the gas brazing machine are cool to avoid burns.

Check mark

Is the room ventilated in case of refrigerant gas leakage?

Check mark

Ensure refrigerant gas is not discharged into the atmosphere and is collected properly.

Check mark

Cautions for Restoration

Check mark

Restore piping using non-oxidation brazing.

Check mark

Wrap the four way valve with wet cloth and provide water to prevent overheating.

Check mark

Pre-Work Checks

Run this procedureArrow right

PCB Removal

Check mark

Pre-removal Safety Check

Check mark

Ensure all power supplies are turned off

Check mark

Wait for 10 minutes after turning off power supplies

Check mark

Main PCB Removal

Check mark

Remove the main PCB [S12] for [HL4] [HN4] on filter

Check mark

Disconnect the PCB connector [S12] and pull out the clamp

Check mark

Disconnect the connector [S10] for [S11] on filter PCB

Check mark

Pull out the clamp and note reassembly instructions

Check mark

Disconnect the connectors [HN3] [HL3] for [HN2] [HL2] on filter PCB

Run this procedureArrow right

Sound Blanket / Thermistor Removal

Check mark

Warning: Wait for 10 minutes after turning off all power supplies before disassembling work.

Check mark

Sound Blanket Removal

Check mark

Remove the 2 screws and remove the partition plate.

Check mark

Remove the sound blanket (top upper).

Check mark

Remove the sound blanket (top lower).

Check mark

Remove the sound blanket (back).

Check mark

Remove the sound blanket (outer).

Check mark

Remove the sound blanket (inner).

Check mark

Thermistor Removal

Run this procedureArrow right

Electrical Box Removal

Check mark

Warning: Wait for 10 minutes after turning off all power supplies before disassembling work.

Check mark

Disassembly Steps

Check mark

Remove the 2 screws and remove the protection plate.

Check mark

Remove the 3 screws and remove the wire fixture.

Check mark

Remove the 7 screws and remove the connecting wire and the power supply wire.

Check mark

Remove the 2 screws and remove the earth / ground wire.

Check mark

Pull out the outdoor temperature thermistor.

Check mark

Remove the 4 screws of the right side panel.

Check mark

Unfasten the 3 hooks and remove the right side panel.

Run this procedureArrow right

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets