Daikin Cooling-Only Outdoor Unit RKS50GVM4
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
PCB Removal
Pre-removal Safety Check
Ensure all power supplies are turned off for at least 10 minutes before starting disassembly.
Main PCB Removal
Remove the main PCB connectors and clamps
Remove screws from the main PCB
Lift the main PCB ASSY.
Unfasten the 4 hooks at the bottom.
Remove the 8 screws.
Unfasten the 2 hooks and remove the main PCB.
Outer Panel Removal
Warning: Wait for 10 minutes or more after turning off all power supplies before disassembling work.
Remove the 4 screws and remove the top panel.
Remove the 4 screws and remove the discharge grille.
Take care not to cut your finger by the fins of the outdoor heat exchanger.
Slide the discharge grille upward and remove it.
Check the number of hooks on the discharge grille.
Remove the 6 screws of the front panel.
Unfasten the 2 right side hooks.
Unfasten the 3 left side hooks and remove the front panel.
Four Way Valve / Electronic Expansion Valve Removal
Safety Precautions
Wait for 10 minutes after turning off all power supplies before starting disassembly work.
Ensure pipes and parts heated by the gas brazing machine are cool to avoid burns.
Is the room ventilated in case of refrigerant gas leakage?
Collect all refrigerant gas to prevent atmospheric discharge.
Cautions for Restoration
Restore the piping by non-oxidation brazing.
Wrap the four way valve with wet cloth and provide water to prevent overheating.
Pre-Work Checks
Electrical Box Removal
Warning: Wait for 10 minutes after turning off all power supplies before disassembling work.
Protection Plate and Wire Fixture Removal
Remove the 2 screws and remove the protection plate.
Remove the 3 screws and remove the wire fixture.
Wire and Panel Disassembly
Remove the 7 screws and remove the connecting wire and the power supply wire.
Remove the 2 screws and remove the earth / ground wire.
Pull out the outdoor temperature thermistor.
Remove the 4 screws of the right side panel.
Sound Blanket / Thermistor Removal
Warning: Wait for 10 minutes after turning off all power supplies before disassembling work.
Sound Blanket Removal
Remove the 2 screws and remove the partition plate.
Remove the sound blanket (top upper).
Remove the sound blanket (top lower).
Remove the sound blanket (back).
Remove the sound blanket (outer).
Remove the sound blanket (inner).
Thermistor Removal
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX