The Daikin Indoor Cooling/Heating Unit FXMQ18PVJU is a versatile HVAC solution designed for efficient climate control in residential and commercial spaces. This unit provides reliable heating and cooling performance, ensuring optimal comfort throughout the year. With advanced technology and energy-efficient operation, it is an ideal choice for modern indoor environments.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more
Daikin Indoor Cooling/Heating Unit FXMQ18PVJU
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Heat Recovery System Vacuuming/Dehydration Maintenance
Warning: This procedure requires trained personnel with PPE!
Choose the type of vacuuming and dehydration
Vacuum pump enables vacuuming down to –100.7 kPa (–14.6 psi)?
Enter the vacuum pump run time in hours
Degree of vacuum reached –100.7 kPa (–14.6 psi) or less?
Leak tests conducted if vacuum did not reach –100.7 kPa (–14.6 psi) or less after 3 hours?
Compressor left at the degree of vacuum of –100.7 kPa (–14.6 psi) or less for a period of 1 hour or more?
Vacuum gauge reading did not rise after leaving the compressor in vacuum state?
Enter the amount of refrigerant charged
Heat Recovery System Maintenance
Check for High Pressure in cooling
Check for High Pressure in heating
Check Thermistor
Check Pressure Sensor
Check for broken wire of the relay wire
Procedure for checking outdoor-outdoor unit transmission wiring for broken wires
Turn OFF the power supply to all equipment
Short circuit between the outdoor-outdoor unit terminal F1 and F2 in the 'Outdoor Unit A'
Conduct continuity checks between the transmission wiring terminal blocks F1 and F2 of the central remote controller using a multimeter
Pressure Check
Warning: This procedure requires trained personnel with PPE!
Compressor PI control in cooling mode
Low pressure protection control
Hot gas bypass control
Superheated degree control with indoor unit electronic expansion valve in cooling mode
Superheated degree control with outdoor unit electronic expansion valve in heating mode
Sign off on the pressure check
Power Transistor Check
Warning: Ensure power is OFF before starting the procedure
Power OFF?
Remove all the wiring connected to the PCB where power transistors are mounted on
Prepare the analog type of multimeter. For the digital type of multimeter, those with diode check function are available for the checking
Power supply turned OFF?
Wait for 10 minutes or more before making measurement of resistance
Select the type of multimeter used
If using the analog type of multimeter, make measurement in resistance measurement mode in the x1 kΩ range
If using the digital type of multimeter, make measurement in diode check mode
Refrigerant Check
Refrigerant Overcharge Check
High pressure reading
Overload control conducted?
Superheated degree of suction gas
Discharge pipe temperature
Subcooled degree of condensate
Refrigerant Shortage Check
Superheated degree of suction gas
Electronic expansion valve open?
Access the parts list for your equipment in MaintainX.
Junction Pipe Kit
KHRP26A250T
Junction Pipe Kit
KHRP26A250T
Junction Pipe Kit
KHRP26A250T
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX