The Daikin Air Conditioner FTXP35M5V1B is a high-efficiency cooling solution designed for residential and commercial applications. Known for its reliability and advanced technology, this model ensures optimal comfort and energy savings, making it a preferred choice for climate control.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Daikin Air Conditioner FTXP35M5V1B

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Daikin Air Conditioner FTXP35M5V1B

Daikin Air Conditioner FTXP35M5V1B

Create an account to install this asset package.

Maintenance Plans for Daikin Air Conditioner Model FTXP35M5V1B

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Battery Replacement

Check mark

Remove the back cover

Check mark

Insert both batteries at once

Check mark

Put the cover back

Run this procedureArrow right

3 Yearly Titanium Apatite Deodorizing Filter and Silver Particle Filter Replacement

Check mark

Warning: Handle the filters with care to avoid damage

Check mark

Tabs on the filter frame removed

Check mark

Old filter removed from the tabs

Check mark

Upload a photo of the new filter ready for installation

Check mark

New filter installed in the filter frame

Check mark

Old filter disposed as non-flammable waste

Check mark

Sign off on the filter replacement

Run this procedureArrow right

6 Monthly Titanium Apatite Deodorizing Filter and Silver Particle Filter Cleaning

Check mark

Warning: Handle the filters with care to avoid damage.

Check mark

Remove the titanium apatite deodorizing and silver particle filters from the tabs

Check mark

Remove the dust from the filter with a vacuum cleaner

Check mark

Soak the filter for 10 to 15 minutes in warm water

Check mark

Do NOT remove the filter from the frame

Check mark

After washing, shake off remaining water and dry the filter in the shade

Check mark

Do NOT wring out the filter when removing water

Check mark

Sign off on the filter cleaning

Run this procedureArrow right

Indoor Unit and User Interface Cleaning

Check mark

NOTICE! Do NOT use gasoline, benzene, thinner polishing powder or liquid insecticide. Possible consequence: Discoloration and deformation

Check mark

Do NOT use water or air of 40°C or higher. Possible consequence: Discoloration and deformation

Check mark

Do NOT use polishing compounds

Check mark

Do NOT use a scrubbing brush. Possible consequence: The surface finishing peels off

Check mark

DANGER: RISK OF ELECTROCUTION. Before cleaning, be sure to stop the operation, turn the breaker off or pull out the supply cord. Otherwise, an electric shock and injury may result

Check mark

Did you stop the operation and turn off the breaker or pull out the supply cord before cleaning?

Check mark

Did you use a soft cloth for cleaning?

Check mark

If stains were difficult to remove, did you use water or a neutral detergent?

Check mark

Sign off on the cleaning procedure

Run this procedureArrow right

2 Weekly Air Filter Cleaning

Check mark

Push the tab at the centre of each air filter, then pull it down

Check mark

Pull out the air filters

Check mark

Remove the titanium apatite deodorizing filter and silver particle filter from the tabs

Check mark

Wash the air filters with water or clean them with a vacuum cleaner

Check mark

Soak in lukewarm water for about 10 to 15 minutes

Check mark

If the dust does NOT come off easily, wash the air filters with a neutral detergent diluted in lukewarm water. Dry the air filters in the shade

Check mark

Be sure to remove the titanium apatite deodorizing and silver particle filters

Check mark

Sign off on the air filter cleaning

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Daikin

Explore Other Assets