The Bunn Coffee Machine CWTF-APS DV is a high-performance commercial brewing system designed for efficiency and reliability. Ideal for cafes and restaurants, this model ensures consistent coffee quality while offering easy maintenance and serviceability. Optimize your coffee brewing process with Bunn's trusted technology.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Bunn Coffee Machine CWTF-APS DV
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Coffee Machine Cleaning
Warning: Always unplug the machine before cleaning
Clean all surfaces with a damp cloth rinsed in mild, non-abrasive, liquid detergent
Check and clean the sprayhead. Ensure the sprayhead holes are open
With the sprayhead removed, insert the deliming spring (provided) all the way into the sprayhead tube. Saw back and forth five or six times
Note: In hard water areas, this may need to be done daily. It will help prevent liming problems in the brewer and takes less than a minute
Sign off on the coffee machine cleaning
Coffee Machine Control Thermostat Replacement
Remove wires from control thermostat leads
Remove the thermostat capillary bulb by firmly pulling-up on the capillary at the tank lid
Remove the one #8-32 screw securing the control thermostat to the component bracket in the trunk
Slide the grommet to the line 4.5\ above the bulb on the new capillary tube"
Insert the capillary bulb through the hole in the tank lid and press the grommet firmly and evenly so that the groove in the grommet fits into the tank lid
Carefully bend the capillary tube so that the tube and bulb inside the tank are in the vertical position
NOTE - The capillary tube must be clear of any electrical termination and not kinked
Early Models: Using two #8-32 screws secure the control thermostat inside the hood
Late Models. Using one #8-32 screw secure the control thermostat to the component bracket inside the trunk
Coffee Machine Control Thermostat Test
Warning: Disconnect the brewer from the power source before starting the test
Locate the blue wire on the control thermostat
Voltage across the blue wire on the control thermostat
If voltage is present as described, proceed to #5. If not, refer to the wiring diagrams and check the brewer wiring harness
Locate the black wire on the control thermostat
Remove the capillary bulb and grommet from the tank
Voltage across the black wire of the control thermostat when the control thermostat is turned fully clockwise
If voltage is present as described, reinstall the capillary tube into the tank to the line 4.5\ (6.0\" for Single CW models) above the bulb
Sign off on the thermostat test
Coffee Machine Dial Timer Replacement
Disconnect the timer socket from the brewer wiring harness and the timer leads from the solenoid valve
Remove the one #8-32 screw securing timer to component bracket
Install new timer on component bracket securing with one #8-32 screw
Upload a photo of the reconnected wires
Readjust the timer dial as required
Sign off on the timer replacement
Coffee Machine Dial Timer Test
Warning: Disconnect the brewer from the power source before starting the procedure
Disconnect the polarized, three pin connector from the brewer wiring harness and rotate the brew timer dial fully counterclockwise
Check the voltage across sockets P2 & P3 (white and black wires) of the female connector with a voltmeter when the ON/OFF is in the ON position (upper)
Voltage reading
If voltage is not present as described, refer to the Wiring Diagrams and check the brewer wiring harness
Check the voltage across the sockets P1 & P2 (blue and white wires) of the female connector with a voltmeter when the ON/OFF switch is in the ON position (upper) and start switch pressed
Voltage reading
If voltage is not present as described, check the brewer wiring harness
Reconnect the three pin connector from main wiring harness to the timer
Access the parts list for your equipment in MaintainX.
Thermostat
29329.1000
Thermostat
29329.1000
Thermostat
29329.1000
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX