The Bunn Hot Water Dispenser H5X--60-208 is a reliable industrial asset designed for high-volume hot water dispensing. This model ensures consistent performance and efficiency, making it ideal for commercial kitchens and foodservice operations. Regular maintenance is essential to maximize its lifespan and operational efficiency.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Bunn Hot Water Dispencer H5X--60-208
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Hot Water Dispencer Electronic Control Replacement
All wires removed from the electronic control board terminals
Six 6-32 screws removed from the electronic control board
Temperature sensor, overflow tube temperature sensor, and indicator wires disconnected from the electronic control board
Temperature sensor, overflow tube temperature sensor, and indicator wires attached to the new electronic control assembly
New electronic control board fastened to its bracket
Upload a photo of the reconnected wires
Initial set-up procedures reviewed
Sign off on the electronic control replacement
Hot Water Dispencer Liquid Level Control Test
Disconnect the dispenser from the power source
Voltage across terminals 3 & 4 of the electronic control board
Check the dispenser wiring harness if voltage was not present as described
Remove the pink wire from terminal 5 of the electronic control assembly
Voltage across terminals 1 & 4 of the electronic control board after connecting the dispenser to the power source
Disconnect the dispenser from the power source
Reconnect the pink wire to terminal 5 of the electronic control assembly
Loosen the compression fitting, remove the probe from the tank lid, and inspect it for mineral deposits. Replace it if necessary. Keep the exposed ends of the probe away from any metal surface of the dispenser
Voltage across terminals 1 & 4 of the electronic control assembly after connecting the dispenser to the power source
Hot Water Dispencer Temperature Control Test
Warning: Disconnect the dispenser from the power source before starting the test
Voltage across terminals 3 & 4 of the electronic control circuit board within the correct range
Voltage across the tank heater terminals within the correct range
Was voltage present as described in the first test?
If voltage was not present as described, contact Bunn-O-Matic to order an electronic control board and temperature sensor for evaluation and proceed to next step
Replace the electronic control board
Voltage across the tank heater terminals within the correct range after replacing the electronic control board
Was voltage present as described in the second test?
If voltage was present as described, the temperature control of the system is operating properly. Return the new electronic control board or temperature sensor to Bunn-O-Matic for credit
Hot Water Dispenser Contactor Test
Warning: Disconnect the dispenser from the power source before starting the test
Disconnect the black wire from the contactor coil to the limit thermostat and black wire from the red wire on the main harness on two wire 240V models
Voltage across the red wire and black wire
Voltage reading
If voltage is not as described, check the wiring harness
Check for continuity between the left and right terminals on the contactor coil
If continuity is not present as described, replace the contactor
Voltage across the upper left terminal and the upper right terminal on the contactor
Voltage reading
Hot Water Dispenser Dispense Switch Replacement
Disconnect the dispenser from the power source
Remove the top cover (3 screws) and front shroud assembly (4 screws)
Remove the top 2 screws and loosen 2 lower screws securing control panel to shroud
Disconnect switch wires from the CBA
Remove the large nut securing the switch
Installation in the reverse order
Sign off on the Dispense Switch Replacement
Access the parts list for your equipment in MaintainX.
Limit Thermostat
23717.0003
Limit Thermostat
23717.0003
Limit Thermostat
23717.0003
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX