Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Advantage Temperature Control Unit SK-1635-LEP
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Electronic Instrument Maintenance
In Warranty Service Incident
Call the factory for diagnostic assistance
Was the control instrument determined to be at fault?
Send a new or reconditioned instrument as a replacement if the instrument is at fault
Return the defective instrument freight pre-paid for full credit
Was the defective instrument returned?
Pay for the instrument if it was not returned
Out of Warranty Service Incident
Call the factory for diagnostic assistance
Pressure Switch Maintenance
Preparation
Shut down unit operations according to section 3.4 in this manual.
Ensure proper lock-out procedures are followed.
Is the system pressure eliminated and the unit's pressure gauges reading '0' pressure?
Pressure Switch Removal
Drain unit by removing the pump casing drain plug.
Remove the capillary connection from the cooling cylinder to the pressure switch.
Remove the brass elbow mounted on the pressure switch.
Remove the electrical connections to the pressure switch.
Instrument Controller Maintenance
Preparation
Disengage process operations according to the procedure outlined in section 3.4.
Ensure all system pressure is relieved and the unit's pressure gauges read '0'.
Disengage main power supply.
Verify the Power light on the display is 'off'.
Accessing the Instrument
Remove the thermoformed front panel and set aside.
Open the hinged electrical cabinet panel cover.
Instrument Removal
Cooling Valve Maintenance
Initial Safety and Preparation
Disengage process operations and verify all system pressure is relieved and the unit's pressure gauges read '0'.
Disengage main power supply and verify the Power light on the display is 'off'.
Access and Disassembly
Remove the lift-off access panel and set aside.
Disconnect the valve wiring harness.
Remove the AVT valve's drip cover.
Motor Driver/Gearbox Servicing
Remove the 2 mounting screws securing the motor/gearbox assembly to the valve bracket.
Heating Cylinder Replacement
Preparation
Disengage operations and ensure all system pressure is relieved
Verify that the unit's pressure gauges read "0"
Disengage main power supply
Verify the Power light on the display is "off"
Access and Drainage
Remove the lift-off access panel and set aside
Drain machine by removing the pump casing drain plug
Heater Removal
Access the parts list for your equipment in MaintainX.
Motor/Pump Assembly AS5 3/4HP ODP 230/460
6207000
Adapter - Iron C2-4551 AS5
414
Pump Case - Iron D2-1839 AS5
771599
Tank Gasket 2-3/8" A-9159 AS5
3444400
Tank Gasket 4-1/2" A2-8748 AS5
3444401
Motor/Pump Assembly AS5 3/4HP ODP 230/460
6207000
Adapter - Iron C2-4551 AS5
414
Pump Case - Iron D2-1839 AS5
771599
Tank Gasket 2-3/8" A-9159 AS5
3444400
Tank Gasket 4-1/2" A2-8748 AS5
3444401
Motor/Pump Assembly AS5 3/4HP ODP 230/460
6207000
Adapter - Iron C2-4551 AS5
414
Pump Case - Iron D2-1839 AS5
771599
Tank Gasket 2-3/8" A-9159 AS5
3444400
Tank Gasket 4-1/2" A2-8748 AS5
3444401
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX