MaintainX Asset Hub logo
EnterprisePricing
ABB

ABB Water Drive ACQ580-01-106A-4

Need answers fast?
Explore the manual using AI.

ABB Water Drive ACQ580-01-106A-4
ABB Water Drive ACQ580-01-106A-4

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for ABB Water Drive ACQ580-01-106A-4

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

ABB Water Drive ACQ580-01-106A-4

ABB Water Drive ACQ580-01-106A-4

Create an account to install this asset package.

Maintenance Plans for ABB Water Drive Model ACQ580-01-106A-4

Integrate maintenance plans directly into your work orders in MaintainX.

1 Yearly Capacitors Check

Check mark

Warning: This procedure requires trained personnel with PPE!

Check mark

The intermediate DC circuit of the drive contains several electrolytic capacitors.

Check mark

Operating time, load, and surrounding air temperature have an effect on the life of the capacitors.

Check mark

Capacitor life can be extended by decreasing the surrounding air temperature.

Check mark

Capacitor failure is usually followed by damage to the unit and an input cable fuse failure, or a fault trip.

Check mark

If you think that any capacitors in the drive have failed, contact ABB.

Check mark

The capacitors must be reformed if the drive has not been powered (either in storage or unused) for a year or more.

Check mark

The manufacturing date is on the type designation label.

Check mark

Check capacitor reforming for spare modules and spare capacitors

Run this procedureArrow right

1 Yearly Drive Inspection

Check mark

Check quality of supply voltage

Check mark

Inspect spare parts

Check mark

Inspect tightness of terminals

Check mark

Inspect dustiness, corrosion or temperature

Check mark

Inspect IP66 (UL Type 4X) frames R1..R3: Drive cover and gasket assembly

Run this procedureArrow right

1 Yearly Heatsink Cleaning

Check mark

Electrical safety in installation, start-up and maintenance

Check mark

Electrical safety precautions

Check mark

WARNING! Obey these instructions. If you ignore them, injury or death, or damage to the equipment can occur.

Check mark

If you are not a qualified electrical professional, do not do installation or maintenance work.

Check mark

Do these steps before you begin any installation or maintenance work.

Check mark

Clearly identify the work location and equipment.

Check mark

Disconnect all possible voltage sources. Make sure that re-connection is not possible. Lock out and tag out.

Check mark

Protect any other energized parts in the work location against contact.

Check mark

Take special precautions when close to bare conductors.

Run this procedureArrow right

20 Yearly Functional Safety Components Replacement

Check mark

Warning: This procedure requires trained personnel with PPE!

Check mark

Are all components within their mission time?

Check mark

If any component is beyond its mission time, proceed with the following steps

Check mark

Choose the type of service done

Check mark

Select the components that have been renewed

Check mark

Enter the age of the oldest component in the circuit

Check mark

Did the safety function pass the post-replacement test?

Check mark

Issues found during the test

Check mark

Sign off on the safety components replacement

Run this procedureArrow right

3 Yearly R1- R2 Auxiliary Cooling Fan Replacement

Check mark

Warning: This procedure requires a qualified electrical professional. Do not attempt if you are not qualified.

Check mark

Before you begin any installation or maintenance work, follow these steps:

Check mark

Identify the work location and equipment

Check mark

Disconnect all possible voltage sources and ensure re-connection is not possible

Check mark

Protect any other energized parts in the work location against contact

Check mark

Take special precautions when close to bare conductors

Check mark

Measure that the installation is de-energized using a quality voltage tester

Check mark

Install temporary grounding as required by the local regulations

Check mark

Ask for a permit to work from the person in control of the electrical installation work

Run this procedureArrow right

Parts for ABB Water Drive ACQ580-01-106A-4

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Braking Resistor

SAFUR125F500

Circuit Breaker, ABB Type

S 803S-B/C 125

Common Mode Filters, ABB Drives

64315811

Du/Dt Filter, ABB Drives

NOCH0120-6x

Fuse, ABB Type

OFAF00H125

Braking Resistor

SAFUR125F500

Circuit Breaker, ABB Type

S 803S-B/C 125

Common Mode Filters, ABB Drives

64315811

Du/Dt Filter, ABB Drives

NOCH0120-6x

Fuse, ABB Type

OFAF00H125

Braking Resistor

SAFUR125F500

Circuit Breaker, ABB Type

S 803S-B/C 125

Common Mode Filters, ABB Drives

64315811

Du/Dt Filter, ABB Drives

NOCH0120-6x

Fuse, ABB Type

OFAF00H125

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from ABB

Explore Other Assets