Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

ABB Water Drive ACQ580-01-106A-4
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Capacitors Check
Warning: This procedure requires trained personnel with PPE!
The intermediate DC circuit of the drive contains several electrolytic capacitors.
Operating time, load, and surrounding air temperature have an effect on the life of the capacitors.
Capacitor life can be extended by decreasing the surrounding air temperature.
Capacitor failure is usually followed by damage to the unit and an input cable fuse failure, or a fault trip.
If you think that any capacitors in the drive have failed, contact ABB.
The capacitors must be reformed if the drive has not been powered (either in storage or unused) for a year or more.
The manufacturing date is on the type designation label.
Check capacitor reforming for spare modules and spare capacitors
1 Yearly Drive Inspection
Check quality of supply voltage
Inspect spare parts
Inspect tightness of terminals
Inspect dustiness, corrosion or temperature
Inspect IP66 (UL Type 4X) frames R1..R3: Drive cover and gasket assembly
1 Yearly Heatsink Cleaning
Electrical safety in installation, start-up and maintenance
Electrical safety precautions
WARNING! Obey these instructions. If you ignore them, injury or death, or damage to the equipment can occur.
If you are not a qualified electrical professional, do not do installation or maintenance work.
Do these steps before you begin any installation or maintenance work.
Clearly identify the work location and equipment.
Disconnect all possible voltage sources. Make sure that re-connection is not possible. Lock out and tag out.
Protect any other energized parts in the work location against contact.
Take special precautions when close to bare conductors.
20 Yearly Functional Safety Components Replacement
Warning: This procedure requires trained personnel with PPE!
Are all components within their mission time?
If any component is beyond its mission time, proceed with the following steps
Choose the type of service done
Select the components that have been renewed
Enter the age of the oldest component in the circuit
Did the safety function pass the post-replacement test?
Issues found during the test
Sign off on the safety components replacement
3 Yearly R1- R2 Auxiliary Cooling Fan Replacement
Warning: This procedure requires a qualified electrical professional. Do not attempt if you are not qualified.
Before you begin any installation or maintenance work, follow these steps:
Identify the work location and equipment
Disconnect all possible voltage sources and ensure re-connection is not possible
Protect any other energized parts in the work location against contact
Take special precautions when close to bare conductors
Measure that the installation is de-energized using a quality voltage tester
Install temporary grounding as required by the local regulations
Ask for a permit to work from the person in control of the electrical installation work
Access the parts list for your equipment in MaintainX.
Braking Resistor
SAFUR125F500
Circuit Breaker, ABB Type
S 803S-B/C 125
Common Mode Filters, ABB Drives
64315811
Du/Dt Filter, ABB Drives
NOCH0120-6x
Fuse, ABB Type
OFAF00H125
Braking Resistor
SAFUR125F500
Circuit Breaker, ABB Type
S 803S-B/C 125
Common Mode Filters, ABB Drives
64315811
Du/Dt Filter, ABB Drives
NOCH0120-6x
Fuse, ABB Type
OFAF00H125
Braking Resistor
SAFUR125F500
Circuit Breaker, ABB Type
S 803S-B/C 125
Common Mode Filters, ABB Drives
64315811
Du/Dt Filter, ABB Drives
NOCH0120-6x
Fuse, ABB Type
OFAF00H125
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX