ABB Uninterruptible Power Supply LP11 Series UL
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
3 Yearly Replacement
- The service life of the battery is from 3 to 6 years, depending on the operating temperature and on the number of discharge cycles.
- As a healthy battery is essential to the performance of the UPS, an automatic battery test is performed regularly to ensure failsafe operation (see section 5.5.1). When the condition of the battery is critical, the warning signal will be activated (buzzer 1x per 8 secs, and alarm message 'Replace battery', see 5.4.2). The batteries must be replaced as soon as possible. Please contact your dealer. Use only UL recognized batteries (BAZR2), valve regulated types.
NOTE: under certain circumstances a manual battery test can result in a false alarm: please see section 5.5.2 QUICK BATTERY TEST.
- Regular deep battery tests are advised in order to re-calibrate the capacity of aging batteries. See section 5.5.3 for more information.
For authorized service personnel only
- Never short the battery terminals. Shorting may cause the battery to burn.
- Avoid charging in a sealed container.
- Proper disposal of batteries is required: refer to your local codes for disposal requirements.
- Never dispose of batteries in a fire: they may explode.
20000 Hours Replacement
- The expected operational life of the cooling fans is approximately 20,000 to 40,000 hours of continuous operation. A high ambient temperature will shorten this operational life.;
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX