MaintainX Asset Hub logo
EnterprisePricing
ABB

ABB Uninterruptible Power Supply 1000U

Need answers fast?
Explore the manual using AI.

ABB Uninterruptible Power Supply 1000U
ABB Uninterruptible Power Supply 1000U

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for ABB Uninterruptible Power Supply 1000U

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

ABB Uninterruptible Power Supply 1000U

ABB Uninterruptible Power Supply 1000U

Create an account to install this asset package.

Maintenance Plans for ABB Uninterruptible Power Supply Model 1000U

Integrate maintenance plans directly into your work orders in MaintainX.

3 Monthly Battery Inspection and Manual Battery Test

Check mark

Warning: Perform mandatory Battery maintenance per Battery’s manufacturer product manual. This includes electrical and thermal measurements, inspection, cleaning, replacement and re-torque of connections. Failure to perform proper maintenance on the Battery, per the Battery manufacturer’s recommendation, including scheduled Battery replacement, may result in thermal damage to the equipment and an increased risk of personnel injury.

Check mark

ABB declines any responsibility for any damage to the system and the surrounding caused by Battery when the Battery maintenance program is provided by other than ABB itself and ABB authorized partners

Check mark

We recommend a periodic Manual Battery Test, especially if the Automatic Battery Test is disabled, in order to verify if the Battery can provide the expected backup time in case of Utility Failure.

Check mark

We recommend that this test is performed at least every 3 months, especially if the Battery is not sufficiently discharged during normal operation.

Check mark

The discharge time you use should be at least half of the Battery runtime.

Check mark

For Battery Test setting, a “Service Code” is required to enter user set-up parameters. The start-up technician has access to this “Service Code” and can program this feature during start-up

Check mark

Please consider that, if you did a full Battery Test to verify the full runtime of the Battery, the charger needs at least 8 hours to recharge the Battery up to 90% of its capacity.

Check mark

Long shut-down periods of the UPS system. To guarantee that the Battery is fully charged, the UPS system should be in operation for at least 12 hours every 3 months. If not, the Battery may be permanently damaged.

Check mark

Battery maintenance performed as per manufacturer's manual?

Run this procedureArrow right

20 000 Hourly / 12 Monthly UPS Preventive Maintenance Service Check

Check mark

Warning: All maintenance and service works must be performed by an ABB Service Technician only!

Check mark

A UPS system, like other electrical equipment, needs periodic preventive maintenance. A regular maintenance check guarantees higher reliability of your safe power supply.

Check mark

ABB recommends to perform the first service within 12 months from the commissioning date or within 18 months from delivery date.

Check mark

Subsequent services to perform every 12 months.

Check mark

Preventive maintenance work on the UPS can be done only by an ABB Service Technician.

Check mark

If the lamp lights up during normal operation, the Unit has not been serviced for the last 20 000 hours by an ABB Service Technician.

Check mark

Some components of the UPS which need periodic maintenance, if not replaced, could cause a reliability reduction of the supply system.

Check mark

Never ignore a Service Check alarm!

Check mark

Failure to perform mandatory preventative maintenance on components documented in the UPS product manual may result in thermal damage to the equipment, its surroundings and an increased risk of personnel injury.

Run this procedureArrow right

Parts for ABB Uninterruptible Power Supply 1000U

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

UPS Model MegaFlex 1000

4NWP106510R0002

Lithium-Ion Battery Samsung (Model PHR3462-001A, 136S)

136S

UPS Model MegaFlex 1000

4NWP106510R0002

Lithium-Ion Battery Samsung (Model PHR3462-001A, 136S)

136S

UPS Model MegaFlex 1000

4NWP106510R0002

Lithium-Ion Battery Samsung (Model PHR3462-001A, 136S)

136S

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from ABB

Explore Other Assets