MaintainX, an Autodesk company
EnterprisePricing
York

York Single Package Air Conditioner ZJ078E24R4B5EAA1A1

Need answers fast?
Explore the manual using AI.

York Single Package Air Conditioner ZJ078E24R4B5EAA1A1
York Single Package Air Conditioner ZJ078E24R4B5EAA1A1

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for York Single Package Air Conditioner ZJ078E24R4B5EAA1A1

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

York Single Package Air Conditioner ZJ078E24R4B5EAA1A1

York Single Package Air Conditioner ZJ078E24R4B5EAA1A1

Create an account to install this asset package.

Maintenance Plans for York Single Package Air Conditioner Model ZJ078E24R4B5EAA1A1

Integrate maintenance plans directly into your work orders in MaintainX.

Joints Leaks Check

Check mark

Safety Precautions

Check mark

Ensure no open flames are present in the area.

Check mark

Use only approved pipe dope for assembling pipes.

Check mark

Ensure the main shut-off valve is open to admit normal gas pressure.

Check mark

Leak Detection

Check mark

Prepare a commercially available soap solution for leak detection.

Check mark

Apply the soap solution to all joints and connections.

Check mark

Check each joint for bubbles indicating a leak.

Check mark

Post-Check Actions

Run this procedureArrow right

Initial 24 Hours Belt Tension Check

Check mark

Belt Tension Adjustment

Check mark

Loosen six nuts (top and bottom) A

Check mark

Adjust by turning (B)

Check mark

Ensure nuts (C) are not loosened

Check mark

Use belt tension checker to apply perpendicular force to one belt at midpoint of the span

Check mark

Enter the deflection distance obtained

Check mark

Use a straight edge from sheave to sheave as reference line to determine deflection distance from normal position

Check mark

Record the recommended deflection force for the belt section

Check mark

Was the belt tension checked at least two times during the first 24 hours of operation?

Run this procedureArrow right

Blower Rotation Check

Check mark

Initial Inspection

Check mark

Verify that the ZJ078-150 unit is properly phased at the factory.

Check mark

Is the electrical connection to the unit correctly phased?

Check mark

Compressor Rotation Check

Check mark

Is the compressor rotating in the correct direction?

Check mark

Check for signs of misphasing in the scroll compressor

Check mark

Blower Rotation Check

Check mark

Is the supply air blower rotating in the correct direction?

Check mark

Is the line voltage at the unit point of power connection correctly phased?

Run this procedureArrow right

Filter Cleaning

Check mark

Filter Inspection

Check mark

Check that all filters are installed ahead of the evaporator coil

Check mark

Inspect filters for dirt and debris

Check mark

Filter Maintenance

Check mark

Clean or replace dirty filters with the same size and type

Check mark

Ensure the unit is not operated without properly installed filters

Check mark

Post Maintenance Check

Check mark

Verify panel latches are properly positioned to maintain an airtight seal

Run this procedureArrow right

Manifold Gas Pressure Maintenance

Check mark

Preparation

Check mark

Turn off all power to the unit

Check mark

Connect a manometer to the outlet pressure port on the gas valve

Check mark

Remove plastic cap covering HI and LO pressure adjustment screws

Check mark

Second Stage Pressure Adjustment

Check mark

Turn on power to the unit

Check mark

Set thermostat to call for second stage heat and start furnace

Check mark

Adjust second stage (HI) manifold pressure using a screwdriver

Check mark

Is the second stage manifold pressure within 3.5 IWG ± 0.3?

Run this procedureArrow right

Parts for York Single Package Air Conditioner ZJ078E24R4B5EAA1A1

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

Ducted Systems Gas Piping Accessory Kit (Nipples, Fittings, and Gas Cock)

1GP0405

LP Gas Conversion Kit

1NP0442

Optional CO2 Space Sensor Kit

2AQ04700524

Optional CO2 Sensor Kit

2AQ04700624

Mobile Access Portal (MAP) Gateway (Portable) Source 1

S1-JC-MAP1810-OP

Ducted Systems Gas Piping Accessory Kit (Nipples, Fittings, and Gas Cock)

1GP0405

LP Gas Conversion Kit

1NP0442

Optional CO2 Space Sensor Kit

2AQ04700524

Optional CO2 Sensor Kit

2AQ04700624

Mobile Access Portal (MAP) Gateway (Portable) Source 1

S1-JC-MAP1810-OP

Ducted Systems Gas Piping Accessory Kit (Nipples, Fittings, and Gas Cock)

1GP0405

LP Gas Conversion Kit

1NP0442

Optional CO2 Space Sensor Kit

2AQ04700524

Optional CO2 Sensor Kit

2AQ04700624

Mobile Access Portal (MAP) Gateway (Portable) Source 1

S1-JC-MAP1810-OP

Unlock
efficiency with MaintainX Assist

MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from York

Explore Other Assets