Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Vulcan Heavy Duty Gas Griddle ASA24
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Momentary Power Switch Replacement
Safety Precautions
Disconnect the electrical power to the machine
Follow lockout / tagout procedures
Switch Removal
Remove FRONT PANEL
Label wires connected to the power switch
Disconnect wires from power switch
Squeeze switch retainers
Slide switch out through front of panel
Thermostat Valve Assembly Replacement
Safety Precautions
Disconnect the electrical power to the machine and follow lockout / tagout procedures
Shut off the gas before servicing the unit and follow lockout / tagout procedures
Check all gas joints disturbed during servicing for leaks using a soap and water solution
Remove FRONT PANEL
Disconnect gas line
Remove screws securing thermostat mounting bracket to frame
Pull capillary tube out from underneath griddle plate
Transfer fittings from old thermostat to new thermostat using thread sealant
Gas Pressure Measurement Service
Safety Precautions
Check all gas joints disturbed during servicing for leaks using a soap and water solution.
Preparation
Turn the gas supply off at a manual shutoff valve.
Remove the control panel.
Pressure Measurement
Remove the pressure tap plug and attach manometer.
Turn gas back on.
Light pilot(s).
Thermostat Calibration
Temperature Measurement
Observe and record temperatures at the center points of the cooking zones using a Surface Probe temperature measurement device
Thermostat Setting and Stabilization
Set thermostats to 350°F and allow to stabilize
Temperature Recording and Calculation
Record the temperature tester readouts for each zone for 3 cycles
Calculate total average temperature for each zone
Temperature Verification
Is the temperature within 350°F ±15°F?
Burner Adjustment
Initial Setup
Ensure the burner is turned off and cool before starting adjustments.
Gather necessary tools for adjustment.
Air Shutter Adjustment
Loosen the screw on the venturi.
Adjust the air shutter to eliminate yellow tips on the burner flames.
Tighten the screw to lock the air shutter in place.
Final Check
Is the flame blue and steady without yellow tips?
Access the parts list for your equipment in MaintainX.
Aluminum Foil Tape
7631421
Adapter
H23-226
Aluminum Foil Tape
7631421
Adapter
H23-226
Aluminum Foil Tape
7631421
Adapter
H23-226
MaintainX Assist is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX