Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Vilter Manufacturing Compressor Unit VSS128
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Daily Compressor Unit Maintenance
Check oil levels
Check all pressure and temperature readings
Check micronic oil filter inlet and outlet pressures for excessive pressure drop
Is the pressure drop across the micronic oil filter greater than 45 psi?
Clean strainers each time filter cartridge is replaced
Check compressor sound for abnormal noises
Check shaft seals for excessive oil leakage
Is the oil leakage within the normal range (6 to 15 drops per hour)?
Oil Separator Coalescing Filter Replacement
Safety Precautions
Ensure adequate ventilation and refrigerant vapor detectors are in place as per ASHRAE standards.
Wear rubber gloves and a face shield when working with condensate or oil.
Use appropriate lifting devices and additional personnel for heavy components.
Removal
Isolate the compressor unit.
Install lifting eyes on oil separator manhole cover, if required.
Secure appropriate lifting device to oil separator manhole cover.
Remove all bolts except top four bolts securing oil separator manhole cover to oil separator vessel.
1 Weekly Compressor Unit Maintenance
Check the refrigeration system for leaks with a suitable leak detector
Oil Pressure and Log Review
Enter the oil pressure reading
Review the microprocessor log and log sheets
Check refrigerant levels in vessels
200 Hourly Oil Filter Replacement
Safety Precautions
Ensure adequate ventilation and refrigerant vapor detectors are in place as per ASHRAE standards.
Wear rubber gloves and a face shield to avoid skin contact with oil.
Preparation
Shut down the compressor unit as per the Stopping/Restarting procedure in Section 4.
Isolate the compressor unit as per the Compressor Unit Isolation procedure.
Drain Oil From Isolated Oil Line
Close oil supply valve and oil filter outlet valve.
Remove plug from drain valve on oil pump strainer.
Slide Valve Command Shaft Assembly Replacement
Removal
Shut down and isolate compressor unit
Remove actuator
Remove components securing the command shaft assembly
Remove the command shaft and mounting plate from the compressor
Installation
Install a new o-ring (446) into the groove on the compressor discharge manifold
Use clean compressor lubricating oil on the o-ring
Install the command shaft onto the compressor discharge manifold
Access the parts list for your equipment in MaintainX.
Coils For Solenoid Valves 110-120VAC
3389DA
Coils For Solenoid Valves 110-120VAC Green
3389DB
Coils For Solenoid Valves 110VAC
3389DC
Coils For Solenoid Valves 220VAC
3389DD
Coils For Solenoid Valves 220VAC W/110VAC LED Box
3389DD1
Coils For Solenoid Valves 110-120VAC
3389DA
Coils For Solenoid Valves 110-120VAC Green
3389DB
Coils For Solenoid Valves 110VAC
3389DC
Coils For Solenoid Valves 220VAC
3389DD
Coils For Solenoid Valves 220VAC W/110VAC LED Box
3389DD1
Coils For Solenoid Valves 110-120VAC
3389DA
Coils For Solenoid Valves 110-120VAC Green
3389DB
Coils For Solenoid Valves 110VAC
3389DC
Coils For Solenoid Valves 220VAC
3389DD
Coils For Solenoid Valves 220VAC W/110VAC LED Box
3389DD1
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX