MaintainX Asset Hub logo
EnterprisePricing
Topcon

Topcon Total Station IS-01

Need answers fast?
Explore the manual using AI.

Topcon Total Station IS-01
Topcon Total Station IS-01

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Topcon Total Station IS-01

Topcon Total Station IS-01

Create an account to install this asset package.

Maintenance Plans for Topcon Total Station Model IS-01

Integrate maintenance plans directly into your work orders in MaintainX.

Compensation Systematic Error Adjusting

Check mark

Level the instrument properly with the plate level

Check mark

Press the [ADJUST] icon from the main menu

Check mark

Press the [3AXIS COMPENSATION] key

Check mark

Press the [ADJUST] key

Check mark

Collimate target A (around 0° in horizontal within ±3°) in normal telescope setting

Check mark

Press the [SET] key ten times

Check mark

Turn the telescope in reverse telescope setting

Check mark

Collimate target A in reverse telescope setting

Check mark

Press the [SET] key ten times

Run this procedureArrow right

Instument Collimating

Check mark

Set up the instrument

Check mark

Enter the distance of clear sights in meters

Check mark

Is the instrument leveled properly with the plate level?

Check mark

Sight Point A

Check mark

Is the telescope pointed in the opposite direction after rotating 180° or 200G around the horizontal axis?

Check mark

Sight Point B

Check mark

Is the instrument rotated 180° or 200G around the vertical axis?

Check mark

Sight Point A again

Check mark

Sight Point C

Run this procedureArrow right

Instument Constant Value Seting

Check mark

Follow the steps below to set the instrument constant value:

Check mark

Press the [ADJUST] icon from the main menu

Check mark

Press the [INST. CONSTANT] key

Check mark

Press the [PRISM] key

Check mark

Input value

Check mark

Press the [SET] key

Check mark

The display should return to the previous menu

Run this procedureArrow right

Laser Pointer Optical Axis Adjusting

Check mark

Warning: This procedure requires trained personnel with PPE!

Check mark

Rubber caps removed from the top of the instrument

Check mark

Hexagonal wrench used to adjust screws A, B, and C

Check mark

Laser pointer adjusted to coincide with the point of intersection

Check mark

Screws A, B, and C tightened equally

Check mark

Rubber caps of the adjustment screws not lost

Check mark

Operation keys placed on the telescope eyepiece side

Check mark

Laser pointer turned on

Check mark

Sign off on the laser pointer optical axis adjustment

Run this procedureArrow right

Laser Pointer Optical Axis Check

Check mark

Prepare the target

Check mark

Draw a target on the center of a piece of graph paper or white paper

Check mark

Set up the target

Check mark

Distance of the target from the IS in meters

Check mark

Turn on the instrument

Check mark

Instrument turned on?

Check mark

Check the laser pointer's optical axis

Check mark

Distance of the center of the laser pointer from the point of intersection in mm

Check mark

Is the center of the laser pointer within about 6 mm of the point of intersection?

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Topcon

Explore Other Assets