MaintainX Logo
EnterprisePricing
Stryker

Stryker Stryker Fifth Wheel 1105 1105

Need answers fast?
Explore the manual using AI.

Stryker Stryker Fifth Wheel 1105 1105
Stryker Stryker Fifth Wheel 1105 1105

The Stryker Fifth Wheel 1105 is a robust industrial asset designed for heavy-duty applications. Known for its reliability and performance, this fifth wheel enhances towing capabilities and ensures optimal safety in transportation operations. Regular maintenance is essential to maximize its lifespan and efficiency.

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Stryker Stryker Fifth Wheel 1105 1105

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Stryker Stryker Fifth Wheel 1105 1105

Stryker Stryker Fifth Wheel 1105 1105

Create an account to install this asset package.

Maintenance Plans for Stryker Stryker Fifth Wheel 1105 Model 1105

Integrate maintenance plans directly into your work orders in MaintainX.

Stretcher Cleaning

Check mark

WARNING: If your unit is equipped with the optional electric lift/litter, unplug the power cord from the power outlet before transporting or cleaning the unit. Do not steam clean the unit.

Check mark

These instructions are intended to provide recommended cleaning methods for Model 1105 Prime Series stretchers.

Check mark

These units are designed to be power-washable. The unit may show some signs of oxidation or discoloration from continuous washing.

Check mark

No degradation of the stretcher’s performance characteristics or functionality will occur due to power washing as long as the proper procedures are followed.

Check mark

RECOMMENDED CLEANING METHOD

Check mark

Followed the cleaning solution manufacturer’s dilution recommendations exactly?

Check mark

Used standard hospital surgical cart washer for power washing?

Check mark

Did not replace the mattress on the stretcher until the unit is completely dry?

Check mark

CAUTION! Before returning the unit to service after cleaning, verify that labels are intact, raise/lower the stretcher, lock the brake/ steer pedal in both positions, latch/unlatch the siderails, and raise/lower the fowler and gatch.

Run this procedureArrow right

1 Year Fifth Wheel Maintenance

Check mark

All fasteners secure

Check mark

Siderails move and latch properly

Check mark

All casters lock with brake pedal engaged

Check mark

All casters secure and swivel properly

Check mark

Inspect each caster and remove any wax or debris which may have collected on the caster or braking mechanism

Check mark

Steer function working properly

Check mark

Check skins for cracks

Check mark

Fowler operates and latches properly

Check mark

Gatch operating properly (Optional equipment)

Run this procedureArrow right

Mattress Disinfecting

Check mark

WARNING: Disinfect the mattress between patients. Failure to do so could result in cross-contamination and infection.

Check mark

WARNING: Some disinfectants may cause damage to the product if used improperly.

Check mark

WARNING: The mattress cover must be completely dry before storage or adding linens.

Check mark

CAUTION: Frequent or prolonged exposure to higher concentration disinfectant solutions may prematurely age the cover fabric.

Check mark

CAUTION: The use of accelerated hydrogen peroxides or quaternaries containing glycol ethers may damage the cover.

Check mark

Ensure surface has been thoroughly cleaned and dried prior to applying disinfectants.

Check mark

Choose the disinfectant used

Check mark

Wipe down the mattress with a clean, dry cloth to remove any excess liquid or disinfectant.

Check mark

Care must be taken to thoroughly rinse and dry covers following disinfection.

Run this procedureArrow right

Mattress Cleaning

Check mark

WARNING: Do not immerse mattress in cleaning or disinfectant solutions. Excess moisture could cause equipment malfunction resulting in equipment damage or patient injury.

Check mark

Do not allow fluid to pool on the mattress. Fluids can cause corrosion of components and may cause the safety and performance of this equipment to become unpredictable.

Check mark

Inspect mattress covers for tears, punctures, excessive wear, and misaligned zippers each time the covers are cleaned. If compromised, the mattress should be removed from service immediately and replaced to prevent cross-contamination.

Check mark

Is the mattress cover intact and without tears, punctures, excessive wear, and misaligned zippers?

Check mark

Stryker mattresses are designed for long-lasting comfort and reliability. The life of the mattress can be adversely affected by an increase in frequency of usage which might include more frequent cleaning and disinfection.

Check mark

Wipe down the entire mattress with a mild soap and water solution to remove foreign material. Was this step completed successfully?

Check mark

Wipe down the mattress with a clean, dry cloth to remove any excess liquid or cleaning agent. Was this step completed successfully?

Check mark

Rinse and dry covers thoroughly following cleaning. Was this step completed successfully?

Check mark

Disinfect as necessary with a hospital grade disinfectant after cleaning has been completed. Was this step completed successfully?

Run this procedureArrow right

Iodine Stains Removing

Check mark

Warning: Follow the instructions carefully to avoid voiding the product's warranty.

Check mark

Enter the amount of Sodium Thiosulfate used

Check mark

Was the stain cleaned immediately after it occurred?

Check mark

Was the solution allowed to soak on the surface before wiping?

Check mark

Was the surface rinsed with clear water before returning the mattress to service?

Check mark

Sign here to confirm that you followed the instructions

Run this procedureArrow right

Parts for Stryker Stryker Fifth Wheel 1105 1105

Access the parts list for your equipment in MaintainX.

Part Name
Part Number

AA Battery

1070-137-029

Scale Control Non-Backlit Keypad

1008-037-820

Staff Control

1008-015-800

Patient Lockout

1008-015-820

Scale/Chaperone Control

1008-237-850

AA Battery

1070-137-029

Scale Control Non-Backlit Keypad

1008-037-820

Staff Control

1008-015-800

Patient Lockout

1008-015-820

Scale/Chaperone Control

1008-237-850

AA Battery

1070-137-029

Scale Control Non-Backlit Keypad

1008-037-820

Staff Control

1008-015-800

Patient Lockout

1008-015-820

Scale/Chaperone Control

1008-237-850

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Stryker

Explore Other Assets