Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Stelrad Group Boiler CX.310
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Manifold Gas Pressure Check
Preparation
Ensure the system is cold and on full load with all temperature controls set at maximum.
Remove the screw in the manifold setting pressure test nipple and connect a suitable gas pressure gauge.
Pressure Adjustment
Light the boiler and allow it to operate for about fifteen minutes to stabilize the burners.
Check the manifold gas pressure.
Adjust the pressure to the figure shown in Table 1 for the appropriate boiler size.
Remove the dust cover over the adjuster.
Using a small screwdriver, turn the screw beneath clockwise to increase or anti-clockwise to decrease pressure.
1 Yearly Gas Valve Replacement
Safety Precautions
Turn OFF the gas supply at the inlet gas cock
Switch OFF and DISCONNECT the electricity supply
Disassembly
Undo the thermocouple and pilot gas pipe connections at the gas valve
Pull out the overheat thermostat connection
Undo the screw securing the grey plastic electrical cover on the valve and lift it off
Undo the earth connection and pull off the two connectors to the gas valve
Undo the overheat thermostat connection at the gas valve
Main Burner Check
Testing the Main Burner
Verify manual ON/OFF operations of controls in the gas control circuit
Flame Failure Safety Device Operation
Turn off the main gas inlet cock (Fig. 12) (C) to extinguish the main burner and pilot burner
Wait for 1½ minutes
Did you hear the thermocouple operated solenoid valve close?
1 Yearly Boiler Cleaning
Preparation
Lift off the lower front panel from the boiler casing.
Remove connections where applicable
Burner Removal
Undo the four nuts securing the burner front plate.
Pull the front plate forwards at the top and lift it out.
Lift out the burners
Remove thermocouple and pilot gas pipe connections at the gas valve.
Pull off the igniter lead at the igniter.
1 Yearly Printed Circuit Board No. 1 Replacement
Safety Precautions
Turn OFF the gas supply at the inlet gas cock
Switch OFF and DISCONNECT the electricity supply
Remove Controls Box
Remove the two screws and washers securing the controls box to the side panels
Lift the controls box off the locating hooks
Disconnect Electrical Connector
Unfasten the two screws securing the plug-in electrical connector to the rear of the control box
Remove the connector
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX