Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Siemens Low Voltage Power Circuit Breaker WLL2S316
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Main Shaft Retainer Removal
Place circuit breaker in an upright position
Press and hold the contacts together
Unscrew the main shaft retainer
Remove the main shaft retainer
Remove the actuator
Attach the cover
Pole Assembly Removal
NOTICE: Damage to the operator mechanism. Failure to install the actuating shaft retainer will cause the closing spring to discharge and will result in the operator mechanism being misaligned and damaged.
Remove hole plug
Press contacts together and hold them
Mount main shaft retainer
Fix main shaft retainer
Sign off on the pole assembly removal
1 Yearly Circuit Breaker Maintenance
DANGER: Hazardous voltage. Will cause death, serious personal injury, or equipment/property damage. Turn off and lock out all power supplying this device before working on this device.
Only qualified personnel should work on this equipment, after becoming thoroughly familiar with all warnings, safety notices, and maintenance procedures contained herein and on the devices.
WARNING: High speed moving parts. Can cause serious personal injury. Discharge the closing spring before inspection and before carrying out any work on the circuit breaker.
Is the worker trained and authorized to energize, de-energize, clear, ground and label circuits and equipment in accordance with established safety practices?
Is the worker trained in the proper care and use of protective equipment in accordance with established safety practices?
Is the worker trained in administering first aid?
The WL circuit breaker is designed and constructed to the highest standard of quality, using the best materials available.
Contact assemblies need to be changed depending on their condition, but no later than - 12,500 operations in FS II up to 1600 A; (3- and 4-pole) - 10,000 operations in FS II 3200 A; (3- and 4-pole) - 10,000 operations in FS III; (3- and 4-pole)
The switchgear operator must determine the inspection intervals depending on the conditions under which the circuit breaker is used: - minimum 1 time per year - after breaking heavy current
Rear Wall Removal
Remove upper screws
Remove lower screws
Support circuit breaker
Rearwall carefully draw off to view the end position retaining springs
Note the position of the end position retaining springs
Separate and remove rearwall
Remove end position retaining springs
Current Sensor Removal
Lay circuit breaker on its side
Remove cover of cable duct
Detach connectors
Remove current sensor covers
Remove current sensors
Sign off on the current sensor removal
Access the parts list for your equipment in MaintainX.
Circuit Breakers Secondary Disconnect Block
WLCNMD
Secondary Disconnect Extension
WLCNMDA
Screw Clamp Terminal (Sigut) System
WLGAUXPLUGP
Spring Clamp Terminal
WLGAUXPLUGT
Ring Terminal System
WLGAUXPLUGR
Circuit Breakers Secondary Disconnect Block
WLCNMD
Secondary Disconnect Extension
WLCNMDA
Screw Clamp Terminal (Sigut) System
WLGAUXPLUGP
Spring Clamp Terminal
WLGAUXPLUGT
Ring Terminal System
WLGAUXPLUGR
Circuit Breakers Secondary Disconnect Block
WLCNMD
Secondary Disconnect Extension
WLCNMDA
Screw Clamp Terminal (Sigut) System
WLGAUXPLUGP
Spring Clamp Terminal
WLGAUXPLUGT
Ring Terminal System
WLGAUXPLUGR
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX