Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Roberts-Gordon Infrared Heater BH-115
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Yearly Gas Piping Inspection
SECTION 9: GAS PIPING
WARNING: Fire Hazard
Gas hose fittings tightened according to Figure 23
Gas hose not cracked or twisted
Gas hose moves during normal operation
36\ (91 cm) long connector of 1/2\" or 3/4\" nominal ID used"
WARNING: Explosion Hazard
Gas hose installed as shown on Page 46, Figure 24
High pressure testing of the gas piping completed
1 Yearly Heater Vicinity Inspection
The Vicinity of the Heater
Do not store or use flammable objects, liquids, or vapors near the heater
Immediately remove these items if they are present
Vehicles and Other Objects
Maintain the clearances to combustibles
Do not hang anything from, or place anything on, the heater
Make sure nothing is lodged underneath the reflector, in between the tubes, or in the decorative or protective grilles included with select models
Immediately remove objects in violation of the clearances to combustibles
See Page 5, Section 3
1 Yearly Reflector Inspection
Reflector.; Support reflector with reflector hanger and support strap.; Reflector must not touch tube.; Make sure there is no dirt, sagging, cracking, or distortion.; Do not operate if there is sagging, cracking, or distortion.; Make sure reflectors are correctly overlapped.; See Page 25, Section 6.5.1.; Clean outside surface with a damp cloth.; Step 6.5.1 Reflector, U-Clip and Reflector Support Installation
The pictorial drawings of the heater construction in Section 6 are schematic only and provide a general guideline of where hangers, reflector supports and U-clips are to be installed
To ensure proper expansion and contraction movement of the reflectors, a combination of U-clips and reflector supports are used
The positioning of reflector supports and U-clips depend on the individual installation
Use either pop rivets or sheet metal screws instead of u-clips when installing end caps and joint pieces in areas where impact and high wind may be a factor
The following rules must be observed
Slide first reflector after burner a minimum 2” (4 cm) through first hanger and ensure reflector end cap is securely fastened via U-clips, pop rivets, or sheet metal screws
Position reflector support with tight screws in middle of first reflector
The overlap at the first and second reflector is a slip overlap
1 Yearly Thermostat Inspection
Thermostat.; There should be no exposed wire or damage to the thermostat.; See Page 47, Section 10.; SECTION 10: WIRING DANGER
Electrical Shock Hazard
Disconnect electric before service
Heater must be properly earthed
Failure to follow these instructions can result in death or electrical shock
Heaters can be controlled using several methods
Normally thermostats are used to control the heaters but they can also be controlled by an energy management system
Section 10.1 illustrates the connection for heaters controlled by a line voltage thermostat
For heaters on a low voltage thermostat, See Page 48, Section 10.2
1 Yearly Tubes Inspection
Check for cracks in the tubes
Check if tubes are connected and suspended securely
Check for sagging, bending, or distortion in the tubes
Check if tubes are clean or need replacement
SECTION 6: HEATER INSTALLATION
WARNING: Severe Injury Hazard. Secure burner to burner tube with nuts and lockwashers. Hang heater with materials with a minimum working load of 75 lbs (33 kg). Failure to follow these instructions can result in death, injury or property damage.
WARNING: Cut/Pinch Hazard. Wear protective gear during installation, operation and service. Edges are sharp. Failure to follow these instructions can result in injury.
Check if the heater is installed in accordance with the instructions
Check if the gas or electrical supply lines are not used to support the heater
Access the parts list for your equipment in MaintainX.
1/2" Rubber Type 1 Gas Hose (Canadian Models)
91412206
180° U-Tube
013359XX
3/4" Rubber Type 1 Gas Hose (Canadian Models)
91412207
4" (10 Cm) U-Bolts
91912500
#8 x 3/8 Hex Washer Head (For Outside Air Collar)
94118106
1/2" Rubber Type 1 Gas Hose (Canadian Models)
91412206
180° U-Tube
013359XX
3/4" Rubber Type 1 Gas Hose (Canadian Models)
91412207
4" (10 Cm) U-Bolts
91912500
#8 x 3/8 Hex Washer Head (For Outside Air Collar)
94118106
1/2" Rubber Type 1 Gas Hose (Canadian Models)
91412206
180° U-Tube
013359XX
3/4" Rubber Type 1 Gas Hose (Canadian Models)
91412207
4" (10 Cm) U-Bolts
91912500
#8 x 3/8 Hex Washer Head (For Outside Air Collar)
94118106
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX