

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Pace Central Filter Unit Arm-Evac 250
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Motor Maintenance
General Tips
Power source turned off before opening the Arm-Evac 250
Arm-Evac and accessories protected from dampness
Arm-Evac 250 not extracting water vapor or steam
Arm-Evac 250 operated with filters
Arm-Evac 250 and ducting hoses not blocked
No extraction of corrosive compounds without checking with PACE
Re-calibration of the Arm-Evac 250 after a filter change out or system configuration change
Motor
1 Monthly Filter Replacement
General Tips: Before opening the Arm-Evac 250, always turn off the power source. Protect the Arm-Evac and accessories from dampness. Do not extract water vapor or steam. The Arm-Evac 250 must not be operated without filters. Impurities in the extracted air can damage the motor pump. Do not allow the Arm-Evac 250 or ducting hoses to become blocked. Do not extract corrosive compounds without checking with PACE. Re-calibrate the Arm-Evac 250 whenever a filter change out or system configuration change occurs.
Filter Replacement
Pre-Filter: This filter removes coarse particles from the air. In general, the pre-filter must be changed on a monthly basis. However, depending on your particular process, the filter may need to be changed more or less frequently.
Main Filters: Fume Extraction Filters remove particulates from the air and capture noxious odors and gases. Depending on your particular process, the filter cartridge may need to be changed more or less frequently.
Replacement Procedure
Turn the Power Switch to the Off (“0”) position.
Remove the Filter access cover.
Remove the old Filter Cartridge(s).
Install new Filter(s). Insure that the Pressure Tube (black coiled cable inside filter compartment) does not become kinked when the new Filter is installed. Insure that the airflow arrow on Filter cartridge is pointing downward.
1 Weekly Filter Inspection
General Tips
Before opening the Arm-Evac 250, always turn off the power source.
Protect the Arm-Evac and accessories from dampness.
Do not extract water vapor or steam.
The Arm-Evac 250 must not be operated without filters. Impurities in the extracted air can damage the motor pump.
Do not allow the Arm-Evac 250 or ducting hoses to become blocked.
Do not extract corrosive compounds without checking with PACE.
Re-calibrate the Arm-Evac 250 whenever a filter change out or system configuration change occurs.
Pre-Filter
1 Monthly Accessories Cleaning
General Tips: Before opening the Arm-Evac 250, always turn off the power source. Protect the Arm-Evac and accessories from dampness. Do not extract water vapor or steam. The Arm-Evac 250 must not be operated without filters. Impurities in the extracted air can damage the motor pump. Do not allow the Arm-Evac 250 or ducting hoses to become blocked. Do not extract corrosive compounds without checking with PACE. Re-calibrate the Arm-Evac 250 whenever a filter change out or system configuration change occurs.
Accessories: Monthly cleaning of the Arm-Evac 250 extraction accessories is recommended. Arm-Evac accessories should be cleaned with a non-aggressive cleaning solvent or detergent only. Make sure the Arm-Evac accessories are completely dry before re-use.
Power source turned off before opening the Arm-Evac 250?
Arm-Evac and accessories protected from dampness?
Arm-Evac 250 operated without filters?
Arm-Evac 250 or ducting hoses blocked?
Corrosive compounds extracted without checking with PACE?
Arm-Evac 250 re-calibrated after a filter change out or system configuration change?
Arm-Evac accessories cleaned with a non-aggressive cleaning solvent or detergent?
Access the parts list for your equipment in MaintainX.
Arm-Evac 250 System 220/240V 50 Hz
8889-0250
Arm-Evac 250 System 110V, 60 Hz
8889-0255
Fuse 230 VAC Systems
8884-9966-P5
Fuse 110 VAC Systems
8884-9961-P5
Arm-Evac 250 Pre-Filter
8883-0111-P5
Arm-Evac 250 System 220/240V 50 Hz
8889-0250
Arm-Evac 250 System 110V, 60 Hz
8889-0255
Fuse 230 VAC Systems
8884-9966-P5
Fuse 110 VAC Systems
8884-9961-P5
Arm-Evac 250 Pre-Filter
8883-0111-P5
Arm-Evac 250 System 220/240V 50 Hz
8889-0250
Arm-Evac 250 System 110V, 60 Hz
8889-0255
Fuse 230 VAC Systems
8884-9966-P5
Fuse 110 VAC Systems
8884-9961-P5
Arm-Evac 250 Pre-Filter
8883-0111-P5
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













