Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Ohaus Explorer Balances EX6202
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Operational Test
Power Connection
Connect a functioning Power Adapter to the balance
Plug the Power Cord into a suitable power source
Startup Verification
Verify that the balance start up sequence occurs properly
Note any error codes
Precision Test
Preparation
Warm up the balance for 60 minutes
Calibrate the balance
Precision Test Execution
Verify the display reads 0g
Record the reading after placing a mass near maximum capacity on the center of the Pan
Verify the display returns to 0g ±1d after removing the mass
Repeat the test three times and record each reading
Evaluation
Load Cell Protection Screw Removal
Attention: This process is only needed for 1, 2 and 3 decimal scales.
Place the load cell in front of you, as shown in the picture below.
Remove the screw on your left side.
Remove the screw on the right side.
Remove both screws with shims completely from the load cell.
Store the screws and shims in a safe place.
Repeatability Test
Set Up
Enter the service menu and adjust settings
Record Stability Setting
Record Filter Level Setting
Record Auto Zero Tracking Setting
Record Displayed Units
Record Mass Used
Test Procedure for Non-Approved Models
Zero the instrument
Off-Center Load Test
Preparation
Set AZT (Auto Zero Tracking) to off
Place the test weight in the center of the Weighing Pan
Tare the balance
Weight Movement and Recording
Record the reading at location A
Record the reading at location B
Record the reading at location C
Record the reading at location D
Access the parts list for your equipment in MaintainX.
Function Label EX
83033626
Top Housing Assembly, Terminal EX
30019590
Display, LCD EX
83033622
PCB, Main, Terminal EX
83033620
PCB Interconnect, Terminal EX
83033621
Function Label EX
83033626
Top Housing Assembly, Terminal EX
30019590
Display, LCD EX
83033622
PCB, Main, Terminal EX
83033620
PCB Interconnect, Terminal EX
83033621
Function Label EX
83033626
Top Housing Assembly, Terminal EX
30019590
Display, LCD EX
83033622
PCB, Main, Terminal EX
83033620
PCB Interconnect, Terminal EX
83033621
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.