

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Marley Cooling Tower 4811
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1 Monthly Electric Motor Maintenance
Motor Lubrication and Cleaning
Lubricate the motor according to the manufacturer's instructions.
Remove oil, dust, or scale deposits from the motor.
Clean and lubricate motor at the close of each operating season.
Operational Checks
Ensure there is no interference with the free rotation of the fan drive before starting the motor.
Run the motor for three hours to dry out windings and relubricate bearing surfaces.
Pre-Season Preparation
Ensure bearings are adequately lubricated before returning motor to service at the start of a new operating season.
Cooling Tower Maintenance
Safety Precautions
Ensure mechanical equipment is inoperable during maintenance
Lock out electrical system disconnect switch
Avoid standing, sitting, or walking on top of the tower
Use an appropriate ladder for upper surface maintenance
Wear protective clothing
Makeup Float Valve Maintenance
Check float valve for proper operation
Check float valve for proper water level
1 Weekly Cooling Tower Visual Inspection
WARNING!
Pre-Inspection Safety Measures
Ensure fan motor is locked out
Wear proper personal protective equipment
Visual Inspection
Inspect for bacterial growth
Inspect general operation conditions
Report any bacterial growth to water treatment expert
Component Inspection and Cleaning
Cooling Tower Service
Blowdown Inspection
Check for continuous water discharge during operation
Record the concentration levels of dissolved solids
Enter the blowdown rate percentage
Water Treatment Precautions
Ensure water treatment chemicals are not added via the cold water basin
1 Monthly Bearing Housing Oil Level Check
Bearing Housing Oil Level Check
Check the oil level in the oil cup at shutdown
Is the oil level adequate?
Fill to the proper level with SAE 30 (ISO 100) weight oil if necessary
Start of New Operating Season
Operate until the oil is warm
Drain the warm oil
Refill with SAE 30 (ISO 100) weight oil
Bearing Housing Refill
Access the parts list for your equipment in MaintainX.
V-Belt A75 (60-Cycle)
693531
Motor Sheave (60-Cycle)
082172
Fan Sheave (60-Cycle)
135210
Fan 24 In. Diameter
436741
Bearing Housing 1301SE
C72316
V-Belt A75 (60-Cycle)
693531
Motor Sheave (60-Cycle)
082172
Fan Sheave (60-Cycle)
135210
Fan 24 In. Diameter
436741
Bearing Housing 1301SE
C72316
V-Belt A75 (60-Cycle)
693531
Motor Sheave (60-Cycle)
082172
Fan Sheave (60-Cycle)
135210
Fan 24 In. Diameter
436741
Bearing Housing 1301SE
C72316
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













