Marley Cooling Tower 4812
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Cooling Tower Maintenance
Safety Precautions
Ensure mechanical equipment is inoperable during maintenance
Lock out electrical system disconnect switch
Use appropriate ladder for upper surface maintenance
Wear protective clothing
Makeup Float Valve Maintenance
Check float valve for proper operation
Check water level for proper setting
Basin and Suction Screen Maintenance
1 Monthly Electric Motor Maintenance
Motor Lubrication and Cleaning
Lubricate the motor according to the manufacturer's instructions.
Remove oil, dust, or scale deposits from the motor.
Clean and lubricate motor at the close of each operating season.
Operational Checks
Ensure there is no interference with the free rotation of the fan drive before starting the motor.
Run the motor for three hours to dry out windings and relubricate bearing surfaces.
Pre-Season Preparation
Ensure bearings are adequately lubricated before returning motor to service at the start of a new operating season.
Cooling Tower Service
Blowdown Inspection
Check for continuous water discharge during operation
Enter the current concentration level of dissolved solids
Select the concentration range for treatment schedule
Water Treatment Precautions
Ensure water treatment chemicals are not added via the cold water basin
1 Monthly Bearing Housing Oil Level Check
Bearing Housing Oil Level Check
Check the oil level in the oil cup at shutdown.
Is the oil level in the oil cup adequate?
Fill to the proper level with SAE 30 (ISO 100) weight oil if necessary.
Oil Change at Start of New Operating Season
Operate the system until the oil is warm.
Drain the old oil.
Refill with SAE 30 (ISO 100) weight oil.
Bearing Housing Refill Procedure
Cooling Tower Cleaning
WARNING!
Preparation
Ensure fan motor is locked out
Wear proper personal protective equipment
Inspection and Cleaning
Inspect for concentrations of dirt, scale, and algae
Was a significant concentration of contaminants found?
Perform periodic flushing and cleaning
Water Treatment Program
Access the parts list for your equipment in MaintainX.
V-Belt A75 (60-Cycle)
693531
Motor Sheave (60-Cycle)
094979
Fan Sheave (60-Cycle)
135210
Fan 24 In. Diameter
436741
Bearing Housing 1301SE
C72316
V-Belt A75 (60-Cycle)
693531
Motor Sheave (60-Cycle)
094979
Fan Sheave (60-Cycle)
135210
Fan 24 In. Diameter
436741
Bearing Housing 1301SE
C72316
V-Belt A75 (60-Cycle)
693531
Motor Sheave (60-Cycle)
094979
Fan Sheave (60-Cycle)
135210
Fan 24 In. Diameter
436741
Bearing Housing 1301SE
C72316
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX