The John Deere Tractor 5425 is a robust agricultural machine designed for versatile farming tasks. Known for its reliability and efficiency, this tractor model offers powerful performance and ease of maintenance, making it a preferred choice among farmers and agricultural professionals.
Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

John Deere Tractor 5425
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
1000 Hourly Maintenance
Change primary and secondary air filter elements.
Check unloader valve condition.
Change transmission/hydraulic oil and Filter.
1. Lower rockshaft to remove trapped oil.
2. Remove drain plug from transmission case (A) and drain out oil.
3. If equipped with MFWD axle, also remove drain plug (B) in drop housing.
4. Replace filter (C) while changing oil. Apply a film of oil to new filter gasket and install new filter. Hand tighten only.
5. Refill system with transmission-hydraulic oil. (See Fuels, Lubricants and Coolant section).
6. Wait 5 minutes and check oil level at dipstick (D).
1000 Hourly / Yearly Maintenance
Replace Primary and Secondary Air Filter Elements
Open hood and remove right-side grill panel
Remove air cleaner retaining strap (A)
Release three air cleaner cover retaining clips (B) and remove air cleaner cover (C)
Remove primary (D) and secondary (E) elements
Install new secondary element
Before you install primary element, clean the inside of air cleaner housing and unloader valve with a damp cloth
Install new primary element
Install air cleaner cover
100 Hourly Maintenance
Engine oil and filter changed?
Transmission/hydraulic filter replaced?
Planetary drive oil changed?
MFWD axle oil changed?
Sign off on the 100 hourly maintenance
100 Hourly Maintenance
Check coolant level
Is the level in coolant tank (B) above 'LOW'?
Check engine oil level
Is the oil level between two marks on dipstick (A)?
Fill fuel tank and add diesel conditioner
Is the fuel tank filled and diesel conditioner added?
Drain water and sediment from fuel tank
Is the water and sediment drained from fuel tank?
Check water separator
2000 Hourly / 2 Yearly Maintenance
Flush Cooling System and Replace Thermostat
1. Drain coolant - Remove radiator cap (A). Open drain valve (B) on radiator and drain coolant from radiator. Drain coolant from engine block:
• Open drain plug (C) on left-hand side of engine block.
2. Remove thermostat - Remove thermostat cover, remove thermostat, and reinstall cover (without thermostat). Tighten cap screws to 47 N.m (35 lb-ft).
3. Flush system with water - Close all drain valves/plugs and fill system with clean water. Run engine about 10 minutes to stir up possible rust or sediment. Stop engine and drain water from system before rust and sediment settle.
4. Flush system with Radiator Cleaner - Close all drain valve/plugs, reinstall coolant start aid switch, and fill the cooling system with a good commercial radiator cleaner and water. Follow instructions provided with cleaner. Stop engine and immediately drain system.
5. Flush system with water. - Close all drain valve/plugs, reinstall coolant start aid switch, and fill with clean water to flush the system. Run the engine about 10 minutes, then drain out flushing water.
6. Replace thermostat - Remove thermostat cover (A) and clean off the gasket material. Apply gasket sealant to new gasket and install along with new thermostat. Tighten cap screws to 47 N.m (35 lb-ft).
7. Fill with fresh coolant - Close all drain valve/plugs and fill with a mixture of antifreeze, and coolant conditioner as specified in the ""Fuels, Lubricants and Coolant"" section.
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX