

Turn manuals into instant answers
with your AI-powered assistantTurn manuals into instant answers
with your AI-powered assistant
Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.
Find all the essential guides in one place.
Tensioning Guide
Belt-diagram
C-120 pulleys
+ 13 more
Pre-built workflows to keep your asset running smoothly.
Daily Electrical System Inspection
Replace Roller and Pulley
Install Engine B-120
+ 29 more
Integrate maintenance plans directly into your work orders.
Motion Industries
Applied Industrial Technologies
Electrical Brothers
+ 5 more
Access the parts list for your equipment in MaintainX.
Drive Motor
B2 Rollers
Tensioning System
+ 40 more

Ingersoll Rand Compressor R30
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
16000 Hourly / 4 Yearly Coolant Hoses Replacement
Replace Coolant hoses
The flexible hoses that carry coolant through the cooling system may become brittle with age and will require replacement. Replace them as needed or every four years.
1. Depending on the location of the hose, it may contain compressor coolant. It is recommended to drain the coolant into a clean container. Cover the container to prevent contamination. If the coolant is contaminated, replace with new coolant.
2. Remove the hose.
3. Install the new hose and refill the compressor with coolant.
4. Start the compressor, check for leaks and check coolant level. Refill as necessary.
1 Daily Compressor Check
Check - Connections and hoses for leaks
Check Coolant level
A coolant level sight glass is located on the side of the separator tank. While the compressor is running under load, coolant should always be visible in the sight glass. The normal position is half way. The compressor should be running for at least 40 seconds for this check.
Stop the compressor, ensure the sump pressure is 0 psig and ensure the coolant is still visible in the sight glass.
Adding Coolant
Run the compressor for a minimum of 40 seconds. The coolant level should be visible in the sight glass. If not:
1. Stop the compressor.
2. Isolate the compressor from the external air system.
3. Press the emergency stop to vent the separator tank and airend.
1 Daily No Loss Drain Trap Maintenance
Checking / Cleaning No Loss Drain Trap (where fitted)
Press the test button on the drain and listen for condensate / air passing through the drain.
Is the drain clogged?
If the drain is clogged, replace the no loss drain valve service module. The service module consists of the lower portion of the drain trap and is not serviceable.
Sign off on the drain trap maintenance
2000 Hourly / 1 Yearly Compressor Maintenance
Replace Air filter element
Replace Coolant filter
Replace Separator cartridges
Inspect Starter box power drive filter element
Replace Food-grade Filter Module
Analysis Shock pulse bearing
Analysis Premium Coolant (Ultra/Ultra EL)
Grease All motors (as required)
4000 Hourly / 1 Yearly Compressor Maintenance
Scavenge screen blockage inspection
Replace Starter box power drive filter element
Replace Package pre-filter element
Air-cooled cooling system cleaning
Pressure transducers calibration
Sign off on the compressor maintenance
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX













