MaintainX Logo
EnterprisePricing
Ingersoll Rand

Ingersoll Rand Air Compressor R110IU-140

Need answers fast?
Explore the manual using AI.

Ingersoll Rand Air Compressor R110IU-140
Ingersoll Rand Air Compressor R110IU-140

Turn manuals into instant answers
with your AI-powered assistant
Turn manuals into instant answers
with your AI-powered assistant

PDF MANUAL

Manual for Ingersoll Rand Air Compressor R110IU-140

MAINTENANCE RESOURCES

Complete asset maintenance, one click away

Get instant access to all the maintenance information you need. Empower technicians to perform preventive maintenance with asset packages, ready to use right out of the box.

Documents

Documents & Manuals

Find all the essential guides in one place.

  • CheckTensioning Guide

  • CheckBelt-diagram

  • CheckC-120 pulleys

  • + 13 more

Work Orders

Work Order Templates

Pre-built workflows to keep your asset running smoothly.

  • CheckDaily Electrical System Inspection

  • CheckReplace Roller and Pulley

  • CheckInstall Engine B-120

  • + 29 more

Procedures

Procedures

Integrate maintenance plans directly into your work orders.

  • CheckMotion Industries

  • CheckApplied Industrial Technologies

  • CheckElectrical Brothers

  • + 5 more

Parts

Parts

Access the parts list for your equipment in MaintainX.

  • CheckDrive Motor

  • CheckB2 Rollers

  • CheckTensioning System

  • + 40 more

Ingersoll Rand Air Compressor R110IU-140

Ingersoll Rand Air Compressor R110IU-140

Create an account to install this asset package.

Maintenance Plans for Ingersoll Rand Air Compressor Model R110IU-140

Integrate maintenance plans directly into your work orders in MaintainX.

2000 Hourly / 6 Monthly Air Compressor Maintenance

Check mark

Take coolant sample for fluid analysis

Check mark

Check scavenge screen for blockage, clean if required

Check mark

Check the calibration of the pressure transducer

Run this procedureArrow right

2000 Hourly Motor Bearings Lubrication

Check mark

Airend Bearings

Check mark

Airend bearings are lubricated by the compressor coolant and require no maintenance.

Check mark

Motor Bearings

Check mark

Clean the area around the inlet and outlet plugs before removing the plugs.

Check mark

Add the specified quantity of recommended grease using a hand lever gun.

Check mark

Replace the inlet plug, run the machine for 10 minutes and then replace the outlet plug.

Check mark

Motor Bearings Lubricant Specifications

Check mark

Use MOB SHC220 grease or equivalent.

Check mark

CAUTION! Do not over pack the motor bearings with grease as this may lead to motor failure.

Run this procedureArrow right

8000 Hourly / 2 Yearly Ultra Coolant Replacement

Check mark

Warning: Only trained personnel should perform this procedure.

Check mark

Position a suitable container under the drain plug.

Check mark

Drain plug positioned correctly?

Check mark

Remove the plug and completely drain the coolant.

Check mark

Coolant completely drained?

Check mark

Remove additional coolant from the airend discharge tube and oil coolers from their respective plugs.

Check mark

Additional coolant removed?

Check mark

Replace the coolant filter.

Check mark

Coolant filter replaced?

Run this procedureArrow right

2000 Hourly Coolant Filter Replacement

Check mark

Loosen filter element with the correct tool

Check mark

Remove the element from the housing

Check mark

Place the old element in a sealed bag and dispose of in a safe way

Check mark

Clean the mating face of the housing

Check mark

Remove the new Ingersoll Rand replacement element from its protective package

Check mark

Apply a small amount of lubricant to the element seal

Check mark

Screw the new element down until the seal makes contact with the housing, then hand tighten a further half turn

Check mark

Start the compressor and check for leaks

Check mark

Sign off on the coolant filter replacement

Run this procedureArrow right

1 Yearly Air Filter Replacement

Check mark

1. Open Air Filter

Check mark

• Unscrew the retaining nut and withdraw the old elements

Check mark

• Fit the new element ensuring that the retaining nut is secured

Check mark

2. Cannister Air Filter

Check mark

• Unclip the retaining cap and withdraw the old elements)

Check mark

. Fit new elements) and refit the retaining cap.

Check mark

3. High Dust Air Filter

Check mark

Unscrew the retaining nut and remove the cannister lid

Check mark

Withdraw the old element(s).

Run this procedureArrow right

Unlock efficiency
with MaintainX CoPilot

MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.

Time Lapse Icon

Reduce Unplanned Downtime

Ensure your team follows consistent procedures to minimize equipment failures and costly delays.

Wrench Clock Icon

Maximize Asset Availability

Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.

Dollar Coin Icon

Lower Maintenance Costs

Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.

Thousands of companies manage their assets with MaintainX

DuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterrollDuracellAB InBevErgonTitan AmericaMeritUnivar SolutionsRivianCadrexMagnaMaasPresriteSoutheast PowerInterroll

More from Ingersoll Rand

Explore Other Assets