HAAG STREIT Applanation Tonometer AT 870
Create an account to install this asset package.
Integrate maintenance plans directly into your work orders in MaintainX.
Drum Position Check
In working position, the feeler arm is swivelled and the measuring drum is set to 0. The arm carrying the measuring prism must swing freely between the limit stops on contact.
Feeler arm swings freely between the limit stops on contact
The control weight is to be used for this inspection. The weight rod is engraved with five rings. The middle ring corresponds to a scale value of 0, the rings immediately to its left and right correspond to a value of 2, and both outside scale rings have a value of 6.
Set the measuring drum to 2
Feeler arm moves towards the patient
Move calibration mark 2 on the measuring drum downwards, opposite the fixed index, by a width of one marking
Feeler arm starts to move independently towards the limit stop in the direction of the examiner
Move calibration mark 2 on the measuring drum upwards, opposite the fixed index, by a width of one marking
Feeler arm starts to move into direction of the stop-piece on the patient's side
Tonometer Check
NOTE!: This check must be carried out once a month.
Is the measuring prism properly positioned?
Is the control weight correctly set?
Repeat the check.
Defective devices must be sent immediately to your Haag-Streit representative.
NOTE!: Haag-Streit offers a repair and service package. For further information, please contact your Haag-Streit representative directly.
Sign off on the Tonometer Check
Applanation Tonometer Cleaning
Warning: The preparation instructions provided do not apply to tonometer measuring prisms.
Tonometer measuring prisms must be prepared in accordance with a different manual.
Comply with the stipulated exposure time.
Observe the manufacturer's safety instructions.
Too strong or aggressive disinfectants or cleaning liquids e.g. hydrogen peroxide will damage the finish and coating of the device.
Do not use sprays.
Do not use any towels that drip.
Wring out any soaked towels before use when necessary.
Ensure that no liquid penetrates the device.
Access the parts list for your equipment in MaintainX.
Reusable Tonometer Measuring Prism
7220316
Tonosafe Disposable Tonometer Measuring Prism
7220345
Control Weight
3300346
Reusable Tonometer Measuring Prism
7220316
Tonosafe Disposable Tonometer Measuring Prism
7220345
Control Weight
3300346
Reusable Tonometer Measuring Prism
7220316
Tonosafe Disposable Tonometer Measuring Prism
7220345
Control Weight
3300346
MaintainX CoPilot is your expert colleague, on call 24/7, helping your team find the answers they need to keep equipment running.
Reduce Unplanned Downtime
Ensure your team follows consistent procedures to minimize equipment failures and costly delays.
Maximize Asset Availability
Keep your assets running longer and more reliably, with standardized maintenance workflows from OEM manuals.
Lower Maintenance Costs
Turn any technician into an expert to streamline operations, maintain more assets, and reduce overall costs.
Thousands of companies manage their assets with MaintainX